S3083
SONET/SDH/ATM OC-48 16:1 TRANSMITTER
Table 7. Performance Specifications
Parameter
Min
Typ
Max
Units
Conditions
Nominal VCO Center
Frequency
2.488
GHz
± 20 ppm. Required to meet
SONET output frequency
specification.
Reference Clock
Frequency Tolerance
-100
45
+100
ppm
Reference Clock Input
Duty Cycle
55
%
Reference Clock Rise &
Fall Times
1.5
ns
20% to 80% of amplitude.
Table 8. Output Jitter Generation vs. Ambient Temperature in Still Air (Without Heatslug attached)
Temperature
Max. Jitter Generation
Unit
V
Voltage
3.1
3.3
3.47
0.006
0.007
0.007
0.008
–40˚ C
25˚ C
70˚ C
85˚ C
0.006
0.007
0.008
0.008
0.006
0.007
0.007
0.008
UI (rms)
UI (rms)
UI (rms)
UI (rms)
Note: Data were taken with 100 sweeps on HP test equipment.
12