S2060D 参数 Datasheet PDF下载

S2060D图片预览
型号: S2060D
PDF下载: 下载PDF文件 查看货源
内容描述: 千兆以太网收发器 [GIGABIT ETHERNET TRANSCEIVER]
分类和应用: 网络接口电信集成电路电信电路以太网以太网:16GBASE-T
文件页数/大小: 22 页 / 696 K
品牌: AMCC [ APPLIED MICRO CIRCUITS CORPORATION ]
 浏览型号S2060D的Datasheet PDF文件第1页浏览型号S2060D的Datasheet PDF文件第2页浏览型号S2060D的Datasheet PDF文件第3页浏览型号S2060D的Datasheet PDF文件第4页浏览型号S2060D的Datasheet PDF文件第6页浏览型号S2060D的Datasheet PDF文件第7页浏览型号S2060D的Datasheet PDF文件第8页浏览型号S2060D的Datasheet PDF文件第9页  
GIGABIT ETHERNET TRANSCEIVER
The COM_DET output signal is ACTIVE whenever
EN_CDET is active and the COMMA control charac-
ter is present on the RX[0:9] parallel data outputs.
The COM_DET output signal will be INACTIVE at all
other times.
S2060
Fibre Channel and Gigabit Ethernet Standards re-
quire that the COMMA sync character appears on
the rising edge of the RBC1 signal. In full rate mode
the phase of the data is adjusted such that this re-
quirement is met. No alignment is necessary when
the S2060 is operating in half rate mode since the
output clock frequency is equal to the parallel word
rate (RATEN INACTIVE).
In ethernet applications it is illegal for multiple con-
secutive COMMA characters to be generated. How-
ever, multiple consecutive COMMA characters can
occur in serial backplane applications. The S2060 is
able to operate properly when multiple consecutive
COMMA characters are received: after the first
COMMA is detected and aligned, the RBC0/RBC1
clock operates without glitches or loss of cycles.
Additionally, COM_DET stays high while multiple
COMMAS are being output.
Parallel Output Clock Rate and Data Stretching
The S2060 supports both full rate and half rate out-
puts, selected via the RATEN input. Table 4 shows
the operating rate scenarios. When RATEN is INAC-
TIVE, a data clock is provided on RBC1 at the data
rate. Data should be clocked on the rising edge of
RBC1. When RATEN is ACTIVE the device is in full
rate mode, and complementary TTL clocks are pro-
vided on the RBC0 and RBC1 outputs at 1/2 the
data rate as required by the Gigabit Ethernet Stan-
dard. Data is clocked on the rising edges of both
RBC0 and RBC1. See Figures 11 and 12.
Table 4. Operating Rates
RATEN
0
1
Serial Input
Rate (Gbps)
1.25
.625
RBC0
(MHz)
62.5
N/ A
RCB1
(MHz)
62.5
62.5
Parallel
Output Rate
(Mbps)
125
62.5
Receive Latency
The average receive latency is 8 byte times.
March 7, 2001 / Revision H
5