欢迎访问ic37.com |
会员登录 免费注册
发布采购

PPC440EPX-NPAFFFTS 参数 Datasheet PDF下载

PPC440EPX-NPAFFFTS图片预览
型号: PPC440EPX-NPAFFFTS
PDF下载: 下载PDF文件 查看货源
内容描述: 440EPx的PowerPC嵌入式处理器 [PowerPC 440EPx Embedded Processor]
分类和应用: PC
文件页数/大小: 94 页 / 3193 K
品牌: AMCC [ APPLIED MICRO CIRCUITS CORPORATION ]
 浏览型号PPC440EPX-NPAFFFTS的Datasheet PDF文件第53页浏览型号PPC440EPX-NPAFFFTS的Datasheet PDF文件第54页浏览型号PPC440EPX-NPAFFFTS的Datasheet PDF文件第55页浏览型号PPC440EPX-NPAFFFTS的Datasheet PDF文件第56页浏览型号PPC440EPX-NPAFFFTS的Datasheet PDF文件第58页浏览型号PPC440EPX-NPAFFFTS的Datasheet PDF文件第59页浏览型号PPC440EPX-NPAFFFTS的Datasheet PDF文件第60页浏览型号PPC440EPX-NPAFFFTS的Datasheet PDF文件第61页  
Revision 1.26 – October 15, 2007  
440EPx – PPC440EPx Embedded Processor  
Preliminary Data Sheet  
Table 8. Signal Functional Description (Sheet 1 of 9)  
Notes:  
1. Receiver input has hysteresis  
2. Must pull up (recommended value is 3kΩ to OV  
(EOV  
for Ethernet)  
DD  
DD  
3. Must pull down (recommended value is 1kΩ)  
4. If not used, must pull up (recommended value is 3kΩ to OV  
(EOV  
for Ethernet)  
DD  
DD  
5. If not used, must pull down (recommended value is 1kΩ)  
6. Strapping input during reset; pull-up or pull-down required  
Signal Name  
PCI Interface  
Description  
I/O  
Type  
Notes  
PCIAD00:31  
PCIC0:3/BE0:3  
PCIClk  
Address/Data bus (bidirectional).  
PCI Command/Byte Enables.  
I/O  
I/O  
I
3.3V PCI  
3.3V PCI  
3.3V PCI  
Provides timing to the PCI interface for PCI transactions.  
1, 5  
Indicates the driving device has decoded its address as the  
target of the current access.  
PCIDevSel  
PCIFrame  
I/O  
I/O  
3.3V PCI  
3.3V PCI  
(PCI 2.2 specification requires 8.2KΩ pull up on host system)  
Driven by the current master to indicate beginning and duration  
of an access.  
(PCI 2.2 specification requires 8.2KΩ pull up on host system)  
Indicates that the specified agent is granted access to the bus.  
When the internal arbiter is enabled, output is PCIGnt0. When  
the internal arbiter is disabled, output is Req.  
PCIGnt0/Req  
PCIGnt1:5  
O
O
3.3V PCI  
3.3V PCI  
(PCI 2.2 specification requires 8.2KΩ pull up on host system)  
Indicates that the specified agent is granted access to the bus.  
Used only when internal PCI arbiter enabled.  
Used as a chip select during configuration read and write  
transactions.  
PCIIDSel  
PCIINT  
I
3.3V PCI  
3.3V PCI  
Level sensitive PCI interrupt.  
O
Indicates initiating agent’s ability to complete the current data  
phase of the transaction.  
PCIIRDY  
PCIPar  
I/O  
I/O  
I/O  
3.3V PCI  
3.3V PCI  
3.3V PCI  
(PCI 2.2 specification requires 8.2KΩ pull up on host system)  
Even parity.  
Reports data parity errors during all PCI transactions except a  
Special Cycle.  
PCIPErr  
(PCI 2.2 specification requires 8.2KΩ pull up on host system)  
Indicates to the PCI arbiter that the specified agent wishes to use  
the bus. When the internal arbiter is enabled, input is PCIReq0.  
When internal arbiter is disabled, input is Gnt.  
PCIReq0/Gnt  
I
3.3V PCI  
1, 4  
1, 4  
An indication to the PCI arbiter that the specified agent wishes to  
use the bus. Used only when internal PCI arbiter enabled.  
PCIReq1:5  
PCIReset  
I
3.3V PCI  
3.3V PCI  
Brings PCI device registers and logic to a consistent state.  
O
Reports address parity errors, data parity errors on the Special  
Cycle command, or other catastrophic system errors.  
PCISErr  
PCIStop  
PCITRDY  
I/O  
I/O  
I/O  
3.3V PCI  
3.3V PCI  
3.3V PCI  
(PCI 2.2 specification requires 8.2KΩ pull up on host system)  
Indicates the current target is requesting the master to stop the  
current transaction.  
(PCI 2.2 specification requires 8.2KΩ pull up on host system)  
Indicates the target agent’s ability to complete the current data  
phase of the transaction.  
(PCI 2.2 specification requires 8.2KΩ pull up on host system)  
AMCC Proprietary  
57