 浏览型号PPC405GP-3DE266C的Datasheet PDF文件第44页浏览型号PPC405GP-3DE266C的Datasheet PDF文件第45页浏览型号PPC405GP-3DE266C的Datasheet PDF文件第46页浏览型号PPC405GP-3DE266C的Datasheet PDF文件第47页浏览型号PPC405GP-3DE266C的Datasheet PDF文件第49页浏览型号PPC405GP-3DE266C的Datasheet PDF文件第50页浏览型号PPC405GP-3DE266C的Datasheet PDF文件第51页浏览型号PPC405GP-3DE266C的Datasheet PDF文件第52页  
Revision 2.03 – September 7, 2007  
405GP – Power PC 405GP Embedded Processor  
Data Sheet  
Spread Spectrum Clocking  
Care must be taken when using a spread spectrum clock generator (SSCG) with the PPC405GP. This controller  
uses a PLL for clock generation inside the chip. The accuracy with which the PLL follows the SSCG is referred to  
as tracking skew. The PLL bandwidth and phase angle determine how much tracking skew there is between the  
SSCG and the PLL for a given frequency deviation and modulation frequency. When using an SSCG with the  
PPC405GP the following conditions must be met:  
• The frequency deviation must not violate the minimum clock cycle time. Therefore, when operating the  
PPC405GP with one or more internal clocks at their maximum supported frequency, the SSCG can only lower  
the frequency.  
• The maximum frequency deviation cannot exceed 3%, and the modulation frequency cannot exceed 40kHz.  
In some cases, on-board PPC405GP peripherals impose more stringent requirements (see Note 1).  
• Use the peripheral bus clock (PerClk) for logic that is synchronous to the peripheral bus since this clock tracks  
the modulation.  
• Use the SDRAM MemClkOut since it also tracks the modulation.  
Please refer to the application note Using a Spread Spectrum Clock Generator with the PowerPC 405GP for  
additional details. This application note is available on the AMCC web site at http://www.amcc.com.  
Notes:  
1. The serial port baud rates are synchronous to the modulated clock. The serial port has a tolerance of  
approximately 1.5% on baud rate before framing errors begin to occur. The 1.5% tolerance assumes that the  
connected device is running at precise baud rates. If an external serial clock is used the baud rate is unaffected  
by the modulation.  
2. Operation of the PPC405GP PCI Bridge is unaffected by the use of a SSCG.  
For PCI frequencies of 33.33 MHz and below the PCI controller supports synchronous mode operation. This is  
accomplished by strapping the PPC405GP for synchronous mode PCI and connecting the PCI bus clock to the  
PPC405GP SysClk input. For 33.33 MHz signalling, the PCI specification has no limitation on the amount of  
frequency deviation or modulation that may be applied to the PCI clock. Therefore, the PPC405GP SSCG  
requirements stated above take precedence.  
At PCI frequencies above 33.33 MHz, the PCI controller must be operated in asynchronous mode. When in  
asynchronous mode, the PCI bus clock must be driven into the PPC405GP PCIClk input. In this configuration  
the PCI controller supports the 66.66 MHz PCI clock specification which specifies a maximum frequency  
deviation of -1% at a modulation of between 30 kHz and 33 kHz.  
3. Ethernet operation is unaffected.  
4. IIC operation is unaffected.  
Caution: It is up to the system designer to ensure that any SSCG used with the PPC405GP meets the above  
requirements and does not adversely affect other aspects of the system.  
48  