 浏览型号IBM25NPE405L-3FA133C的Datasheet PDF文件第39页浏览型号IBM25NPE405L-3FA133C的Datasheet PDF文件第40页浏览型号IBM25NPE405L-3FA133C的Datasheet PDF文件第41页浏览型号IBM25NPE405L-3FA133C的Datasheet PDF文件第42页浏览型号IBM25NPE405L-3FA133C的Datasheet PDF文件第44页浏览型号IBM25NPE405L-3FA133C的Datasheet PDF文件第45页浏览型号IBM25NPE405L-3FA133C的Datasheet PDF文件第46页浏览型号IBM25NPE405L-3FA133C的Datasheet PDF文件第47页  
Preliminary  
PowerNP NPe405L Embedded Processor Data Sheet  
DC Electrical Characteristics  
Parameter  
Symbol  
Minimum  
444  
468  
490  
17  
Typical  
497  
565  
590  
23  
Maximum  
543  
676  
700  
36  
Unit  
mA  
mA  
mA  
mA  
mA  
mA  
mA  
W
Active Operating Current for V @ 133MHz  
I
DD  
DD  
Active Operating Current for V @ 200MHz  
I
DD  
DD  
Active Operating Current for V @ 266MHz  
I
DD  
DD  
Active Operating Current for OV @ 133MHz  
I
DD  
ODD  
Active Operating Current for OV @ 200MHz  
I
24  
36  
51  
DD  
ODD  
Active Operating Current for OV @ 266MHz  
I
27  
44  
61  
DD  
ODD  
Active Operating Current for AV  
I
5.5  
6
6.5  
DD  
ADD  
1
P
Active Operating Power @ 133MHz  
1.1  
1.3  
1.6  
DD  
1
P
Active Operating Power @ 200MHz  
Active Operating Power @ 266MHz  
Notes:  
1.4  
1.5  
1.7  
1.8  
W
W
2
DD  
1
P
DD  
2.1  
1. Maximum power is characterized at V =2.7V, OV =3.6V, T =85°C, across the silicon process (worse case to best case),  
DD  
DD  
C
while running an application designed to maximize power consumption. The maximum power values are measured with the  
following clock rate combinations:  
a. CPU=133.33MHz, PLB=66.66MHz, OPB=66.66MHz, EBC=33.33MHz  
b. CPU=200 MHz, PLB=100MHz, OPB=50MHz, EBC=50MHz  
c. CPU=266.66MHz, PLB=66.66MHz, OPB=66.66MHz, EBC=33.33MHz  
Test Conditions  
Output  
Pin  
Clock timing and switching characteristics are specified in accordance  
with operating conditions shown in the table “Recommended DC  
Operating Conditions.” AC specifications are characterized at  
OVDD = 3.00V and TJ = 85°C with the 50pF test load shown in the  
50pF  
figure at right.  