欢迎访问ic37.com |
会员登录 免费注册
发布采购

EPM7064STI44-7 参数 Datasheet PDF下载

EPM7064STI44-7图片预览
型号: EPM7064STI44-7
PDF下载: 下载PDF文件 查看货源
内容描述: 可编程逻辑器件系列 [Programmable Logic Device Family]
分类和应用: 可编程逻辑器件输入元件时钟
文件页数/大小: 66 页 / 1497 K
品牌: ALTERA [ ALTERA CORPORATION ]
 浏览型号EPM7064STI44-7的Datasheet PDF文件第16页浏览型号EPM7064STI44-7的Datasheet PDF文件第17页浏览型号EPM7064STI44-7的Datasheet PDF文件第18页浏览型号EPM7064STI44-7的Datasheet PDF文件第19页浏览型号EPM7064STI44-7的Datasheet PDF文件第21页浏览型号EPM7064STI44-7的Datasheet PDF文件第22页浏览型号EPM7064STI44-7的Datasheet PDF文件第23页浏览型号EPM7064STI44-7的Datasheet PDF文件第24页  
MAX 7000 Programmable Logic Device Family Data Sheet  
MAX 7000 devices offer a power-saving mode that supports low-power  
Programmable  
Speed/Power  
Control  
operation across user-defined signal paths or the entire device. This  
feature allows total power dissipation to be reduced by 50% or more,  
because most logic applications require only a small fraction of all gates to  
operate at maximum frequency.  
The designer can program each individual macrocell in a MAX 7000  
device for either high-speed (i.e., with the Turbo BitTM option turned on)  
or low-power (i.e., with the Turbo Bit option turned off) operation. As a  
result, speed-critical paths in the design can run at high speed, while the  
remaining paths can operate at reduced power. Macrocells that run at low  
power incur a nominal timing delay adder (tLPA) for the tLAD, tLAC, tIC  
,
tEN, and tSEXP, tACL, and tCPPW parameters.  
MAX 7000 device outputs can be programmed to meet a variety of  
system-level requirements.  
Output  
Configuration  
MultiVolt I/O Interface  
MAX 7000 devices—except 44-pin devices—support the MultiVolt I/O  
interface feature, which allows MAX 7000 devices to interface with  
systems that have differing supply voltages. The 5.0-V devices in all  
packages can be set for 3.3-V or 5.0-V I/O pin operation. These devices  
have one set of VCCpins for internal operation and input buffers  
(VCCINT), and another set for I/O output drivers (VCCIO).  
The VCCINTpins must always be connected to a 5.0-V power supply.  
With a 5.0-V VCCINT level, input voltage thresholds are at TTL levels, and  
are therefore compatible with both 3.3-V and 5.0-V inputs.  
The VCCIOpins can be connected to either a 3.3-V or a 5.0-V power  
supply, depending on the output requirements. When the VCCIOpins are  
connected to a 5.0-V supply, the output levels are compatible with 5.0-V  
systems. When VCCIO is connected to a 3.3-V supply, the output high is  
3.3 V and is therefore compatible with 3.3-V or 5.0-V systems. Devices  
operating with VCCIO levels lower than 4.75 V incur a nominally greater  
timing delay of tOD2 instead of tOD1  
.
Open-Drain Output Option (MAX 7000S Devices Only)  
MAX 7000S devices provide an optional open-drain (functionally  
equivalent to open-collector) output for each I/O pin. This open-drain  
output enables the device to provide system-level control signals (e.g.,  
interrupt and write enable signals) that can be asserted by any of several  
devices. It can also provide an additional wired-ORplane.  
20  
Altera Corporation  
 复制成功!