15–6  
Chapter 15: Using the Agilent 3070 Tester for In-System Programming  
Agilent 3070 Development Flow without the PLD ISP Software  
Run the Test Consultant  
Run the Test Consultant to create all of the files for new board development. Once the  
Test Consultant finishes running with this  
setup-only test library, it creates an executable test (without vectors) with the correct  
fixture wiring resource information. Use this file as a template to create the executable  
test’s source code.  
Create Digital Tests  
Create the digital tests, which are required to program the device(s), by copying the  
executable template to the desired program names. For example, if svf2pcf created  
four PCF Files, copy the template file to four executable tests (for example, prog_a,  
prog_b, prog_c, and prog_d) in the digital directory.  
Add these test names to your testorder file and mark them permanent using the  
following syntax:  
test digital "prog_a"; permanent  
test digital "prog_b"; permanent  
test digital "prog_c"; permanent  
test digital "prog_d"; permanent  
Create the Wirelist Information for the Tests  
Compile these executable tests to generate object files (see “Modify the Test Plan”) for  
the setup only versions of the tests. Run Module Pin Assignment to create the  
necessary entries in the wirelist file.  
Next, modify the executable tests so that they contain the vectors to program the  
target device. An includestatement can be used in the executable test, or the vectors  
can be merged into the file. Use the following syntax for the includestatement,  
which should be the last statement in the executable test.  
include "pcf1"  
Remember that the PCF File must reside in the digital directory and must be a digital  
file. To ensure that the digital file is in the correct directory, run the following  
command on the BT-Basic command line:  
load digital "digital/pcf1"  
|
re-save  
You can also use the chtype command at a shell prompt to verify the location of the  
file:  
chtype -n6 digital/pcf1  
Repeat this step for each PCF File.  
Modify the Test Plan  
Add the test statements to the test plan using the following syntax:  
test "digital/prog_a" ! First program file  
test "digital/prog_b" ! Second program file  
test "digital/prog_c" ! Third program file  
test "digital/prog_d" ! Fourth program file  
MAX II Device Handbook  
© October 2008 Altera Corporation  