15–4  
Chapter 15: Using the Agilent 3070 Tester for In-System Programming  
Agilent 3070 Development Flow without the PLD ISP Software  
Step 2: Create a Serial Vector Format File  
The Quartus II software generates SVF Files for programming one or more devices.  
When targeting multiple devices in the same MAX II CPLD family, the Quartus II  
software automatically generates one SVF File to program the devices concurrently.  
Therefore, the programming time for all of the devices approaches the programming  
time for the largest CPLD device in the IEEE Std. 1149.1 JTAG chain.  
Figure 15–2 shows the Create JAM, SVF, or ISC File dialog box (File menu), which is used to  
generate the SVF File.  
Figure 15–2. Create JAM, SVF, or ISC File Dialog Box  
Before creating the SVF File, you must open the Programmer in the Quartus II and  
add the Programmer Object File (.pof) for all the devices in the chain into the  
programmer. Each POF corresponds to a targeted device, respectively.  
In the Create JAM, SVF, or ISC File dialog box, the value in the TCKfrequency box  
should match the frequency that TCKruns at during the test. If you enter a different  
frequency from the one used in actual testing, programming may fail or you may  
experience an excessively long programming time.  
You can also select whether to perform a program or verify operation and optionally  
verify or blank-check the device by turning on programming options. Altera  
recommends generating SVF Files that include verify vectors, which ensure that  
programming failures are identified and a limited amount of additional programming  
time is used. You can generate the necessary SVF File based on the scan-chain  
topology of the board and the Altera devices to be programmed. Once the SVF File is  
generated, it can be given to test engineers for development.  
If a device must be programmed independently, you can generate individual SVF  
Files for each Altera device in the chain. When creating the SVF File for a single device  
in the chain, specify the POF for the device and leave the rest of the devices set to  
<none>. This can be done by selecting Add Device in the Programmer. These devices  
are bypassed during programming. Repeat this process until all targeted devices have  
an SVF File.  