 浏览型号EPF6024ABC256-3的Datasheet PDF文件第43页浏览型号EPF6024ABC256-3的Datasheet PDF文件第44页浏览型号EPF6024ABC256-3的Datasheet PDF文件第45页浏览型号EPF6024ABC256-3的Datasheet PDF文件第46页浏览型号EPF6024ABC256-3的Datasheet PDF文件第48页浏览型号EPF6024ABC256-3的Datasheet PDF文件第49页浏览型号EPF6024ABC256-3的Datasheet PDF文件第50页浏览型号EPF6024ABC256-3的Datasheet PDF文件第51页  
FLEX 6000 Programmable Logic Device Family Data Sheet  
Table 38. External Timing Parameters for EPF6024A Devices  
Parameter  
Speed Grade  
-2  
Unit  
-1  
-3  
Min  
Max  
Min  
Max  
Min  
Max  
tINSU  
2.0 (1)  
0.2 (2)  
2.0  
2.2 (1)  
0.2 (2)  
2.0  
2.6 (1)  
0.3 (2)  
2.0  
ns  
ns  
ns  
tINH  
tOUTCO  
7.4  
8.2  
9.9  
Notes:  
(1) Setup times are longer when the Increase Input Delay option is turned on. The setup time values are shown with the  
Increase Input Delay option turned off.  
(2) Hold time is zero when the Increase Input Delay option is turned on.  
The supply power (P) for FLEX 6000 devices can be calculated with the  
following equations:  
Power  
Consumption  
P = PINT + PIO  
P = (ICCSTANDBY + ICCACTIVE) × VCC + PIO  
Typical ICCSTANDBY values are shown as ICC0 in the “FLEX 6000 Device  
DC Operating Conditions” table on pages 31 and 33 of this data sheet. The  
I
CCACTIVE value depends on the switching frequency and the application  
logic. This value is based on the amount of current that each LE typically  
consumes. The PIO value, which depends on the device output load  
characteristics and switching frequency, can be calculated using the  
guidelines given in Application Note 74 (Evaluating Power for Altera Devices).  
The ICCACTIVE value can be calculated with the following equation:  
µA  
----------------------------  
×
ICCACTIVE = K × fMAX × N × togLC  
MHz × LE  
Where:  
fMAX  
N
=
=
=
Maximum operating frequency in MHz  
Total number of LEs used in a FLEX 6000 device  
Average percentage of LEs toggling at each clock  
(typically 12.5%)  
togLC  
K
=
Constant, shown in Table 39  
Table 39. K Constant Values  
Device  
K Value  
EPF6010A  
EPF6016  
14  
88  
14  
14  
EPF6016A  
EPF6024A  
Altera Corporation  
47  
 
 
 