Operating Conditions
Page 19
Operating Conditions
Table 12 through Table 19 list information about absolute maximum ratings,
recommended operating conditions, DC operating conditions, and capacitance for
configuration devices.
(1)
Table 12. Absolute Maximum Ratings
Symbol Parameter
Supply voltage
Conditions
Min
–2.0
–2.0
—
Max
7.0
7.0
50
Unit
V
(2)
VCC
With respect to GND
(2)
VI
DC input voltage
With respect to GND
V
IMAX
IOUT
PD
DC VCC or GND current
DC output current, per pin
Power dissipation
—
—
mA
mA
mW
° C
° C
° C
–25
—
25
—
250
150
135
135
TSTG
TAMB
TJ
Storage temperature
Ambient temperature
Junction temperature
No bias
–65
–65
—
Under bias
Under bias
Table 13. Recommended Operating Conditions
Symbol
Parameter
Supply voltage for 5.0-V operation
Supply voltage for 3.3-V operation
Input voltage
Conditions
Min
Max
Unit
V
4.75
(4.50)
5.25
(5.50)
(3) (4)
,
VCC
(3) (4)
,
3.0 (3.0)
3.6 (3.6)
V
VCC + 0.3
VI
With respect to GND
–0.3
V
(5)
VO
Output voltage
—
For commercial use
For industrial use
—
0
0
VCC
70
85
20
20
V
° C
° C
ns
TA
Operating temperature
–40
—
—
tR
tF
Input rise time
Input fall time
—
ns
Table 14. DC Operating Conditions
Symbol
Parameter
High-level input voltage
Low-level input voltage
Conditions
Min
2.0
Max
Unit
V
VCC + 0.3
VIH
—
—
(5)
VIL
–0.3
2.4
0.8
—
V
5.0-V mode high-level TTL output
voltage
(6)
IOH = –4 mA DC
V
VOH
3.3-V mode high-level CMOS
output voltage
(6)
IOH = –0.1 mA DC
VCC – 0.2
—
V
(6)
VOL
II
Low-level output voltage
Input leakage current
IOL = 4 mA DC
—
0.4
10
10
V
VI = VCC or GND
VO = VCC or GND
–10
–10
A
A
IOZ
Tri-state output off-state current
January 2012 Altera Corporation
Configuration Devices for SRAM-Based LUT Devices