欢迎访问ic37.com |
会员登录 免费注册
发布采购

EP3C5E144C8N 参数 Datasheet PDF下载

EP3C5E144C8N图片预览
型号: EP3C5E144C8N
PDF下载: 下载PDF文件 查看货源
内容描述: 能够禁用外部JTAG端口 [Ability to disable external JTAG port]
分类和应用: 现场可编程门阵列可编程逻辑PC时钟
文件页数/大小: 348 页 / 6766 K
品牌: ALTERA [ ALTERA CORPORATION ]
 浏览型号EP3C5E144C8N的Datasheet PDF文件第246页浏览型号EP3C5E144C8N的Datasheet PDF文件第247页浏览型号EP3C5E144C8N的Datasheet PDF文件第248页浏览型号EP3C5E144C8N的Datasheet PDF文件第249页浏览型号EP3C5E144C8N的Datasheet PDF文件第251页浏览型号EP3C5E144C8N的Datasheet PDF文件第252页浏览型号EP3C5E144C8N的Datasheet PDF文件第253页浏览型号EP3C5E144C8N的Datasheet PDF文件第254页  
10–4  
Chapter 10: Hot-Socketing and Power-On Reset in the Cyclone III Device Family  
Document Revision History  
The POR circuit of the Cyclone III device monitors the VCCINT, VCCIO (banks 1, 6, 7,  
and 8), and VCCA pins during power-on. The enhanced POR circuit of the Cyclone III  
LS device includes monitoring VCCBAT to ensure that VCCBAT is always at the minimum  
requirement voltage level.  
1
The VCCBAT power supply is the new design security feature power supply introduced  
for Cyclone III LS devices only. Cyclone III devices do not have VCCBAT power supply.  
After Cyclone III device family enters user mode, the POR circuit continues to  
monitor the VCCINT or VCCA pins so that a brown-out condition during user mode is  
detected. If the VCCINT or VCCA voltage sags below the POR trip point during user  
mode, the POR circuit resets the device. If the VCCIO voltage sags during user mode,  
the POR circuit does not reset the device.  
In some applications, it is necessary for a device to wake up very quickly to begin  
operation. Cyclone III device family offers the Fast-On feature to support fast  
wake-up time applications. For Cyclone III device family, the MSEL[3..0]pin settings  
determine the POR time (tPOR) of the device. Fast POR ranges from 3 ms to 9 ms, while  
standard POR ranges from 50 ms to 200 ms.  
If you cannot meet the maximum VCC ramp time requirement, use an external  
component to hold nCONFIGlow until the power supplies have reached their  
minimum recommend operating levels. Otherwise, the device may not properly  
configure and enter user mode.  
f
f
For more information about the MSEL[3..0]pin settings, refer to the Configuration,  
Design Security, and Remote System Upgrades in the Cyclone III Device Family chapter.  
For more information about the VCCBAT pin connection, refer to the Cyclone III Device  
Family Pin Connection Guidelines.  
Document Revision History  
Table 10–1 lists the revision history for this document.  
Table 10–1. Document Revision History (Part 1 of 2)  
Date  
Version  
Changes  
Updated “POR Circuitry” on page 10–3.  
December 2011  
3.3  
Updated hyperlinks.  
Minor text edits.  
December 2009  
July 2009  
3.2  
3.1  
Minor changes to the text.  
Made minor correction to the part number.  
Updated chapter part number.  
Updated “I/O Pins Remain Tristated During Power-Up” on page 10–2.  
Updated “Hot-Socketing Feature Implementation” on page 10–3.  
Updated “POR Circuitry” on page 10–4.  
Updated chapter to new template.  
June 2009  
3.0  
1.2  
October 2008  
Added handnote to the “Cyclone III Hot-Socketing Specifications” section.  
Cyclone III Device Handbook  
Volume 1  
December 2011 Altera Corporation