 浏览型号EP3C120F484C8NES的Datasheet PDF文件第1页浏览型号EP3C120F484C8NES的Datasheet PDF文件第2页浏览型号EP3C120F484C8NES的Datasheet PDF文件第3页浏览型号EP3C120F484C8NES的Datasheet PDF文件第4页浏览型号EP3C120F484C8NES的Datasheet PDF文件第6页浏览型号EP3C120F484C8NES的Datasheet PDF文件第7页浏览型号EP3C120F484C8NES的Datasheet PDF文件第8页浏览型号EP3C120F484C8NES的Datasheet PDF文件第9页  
Chapter 1: Cyclone III Device Data Sheet  
1–5  
Electrical Characteristics  
Table 1–3. Cyclone III Devices Recommended Operating Conditions (Note 1), (2) (Part 2 of 2)  
Symbol  
Parameter  
Conditions  
Min  
0
Typ  
Max  
85  
Unit  
For commercial use  
For industrial use  
°C  
°C  
–40  
100  
TJ  
Operating junction temperature  
For extended temperature  
–40  
–40  
125  
125  
°C  
°C  
(5)  
For automotive use  
Standard power-on reset  
50 µs  
50 µs  
50 ms  
3 ms  
10  
mA  
(POR) (6)  
tRAMP  
Power supply ramp time  
Fast POR (7)  
Magnitude of DC current across  
PCI-clamp diode when enabled  
IDiode  
Notes to Table 1–3:  
(1) VCCIO for all I/O banks must be powered up during device operation. All VCCA pins must be powered to 2.5 V (even when PLLs are not used), and  
must be powered up and powered down at the same time.  
(2) VCCD_PLL must always be connected to VCCINT through a decoupling capacitor and ferrite bead.  
(3) The VCC must rise monotonically.  
(4) All input buffers are powered by the VCCIO supply.  
(5) The I7 devices support extended operating junction temperature up to 125°C (usual range is –40°C to 100°C). When using I7 devices at the  
extended junction temperature ranging from –40°C to 125°C, select C8 as the target device when designing in the Quartus® II software. The I7  
devices meet all C8 timing specifications when I7 devices operate beyond 100°C and up to 125°C.  
(6) POR time for Standard POR ranges between 50–200 ms. Each individual power supply should reach the recommended operating range within  
50 ms.  
(7) POR time for Fast POR ranges between 3–9 ms. Each individual power supply should reach the recommended operating range within 3 ms.  
DC Characteristics  
This section lists the I/O leakage current, pin capacitance, on-chip termination (OCT)  
tolerance, and bus hold specifications for Cyclone III devices.  
Supply Current  
Standby current is the current the device draws after the device is configured with no  
inputs or outputs toggling and no activity in the device. Use the Excel-based early  
power estimator (EPE) to get the supply current estimates for your design because  
these currents vary largely with the resources used. Table 1–4 lists I/O pin leakage  
current for Cyclone III devices.  
Table 1–4. Cyclone III Devices I/O Pin Leakage Current (Note 1), (2) (Part 1 of 2)  
Symbol  
II  
IOZ  
Parameter  
Conditions  
Device  
Min  
Typ  
Max  
Unit  
Input pin leakage current  
VI = 0 V to VCCIOMAX  
–10  
10  
μA  
Tristated I/O pin leakage  
current  
VO = 0 V to VCCIOMAX  
–10  
10  
μA  
© January 2010 Altera Corporation  
Cyclone III Device Handbook, Volume 2