欢迎访问ic37.com |
会员登录 免费注册
发布采购

EP3C16Q164C6ES 参数 Datasheet PDF下载

EP3C16Q164C6ES图片预览
型号: EP3C16Q164C6ES
PDF下载: 下载PDF文件 查看货源
内容描述: 的Cyclone III器件手册 [Cyclone III Device Handbook]
分类和应用:
文件页数/大小: 274 页 / 7308 K
品牌: ALTERA [ ALTERA CORPORATION ]
 浏览型号EP3C16Q164C6ES的Datasheet PDF文件第230页浏览型号EP3C16Q164C6ES的Datasheet PDF文件第231页浏览型号EP3C16Q164C6ES的Datasheet PDF文件第232页浏览型号EP3C16Q164C6ES的Datasheet PDF文件第233页浏览型号EP3C16Q164C6ES的Datasheet PDF文件第235页浏览型号EP3C16Q164C6ES的Datasheet PDF文件第236页浏览型号EP3C16Q164C6ES的Datasheet PDF文件第237页浏览型号EP3C16Q164C6ES的Datasheet PDF文件第238页  
9–76
Chapter 9: Configuration, Design Security, and Remote System Upgrades in the Cyclone III Device Family
Remote System Upgrade
shows the block diagrams to implement remote system upgrade with the
AS and AP configuration schemes.
Figure 9–33. Remote System Upgrade Block Diagrams for AS and AP Configuration Schemes
Serial Configuration Device
Parallel Flash Memory
Cyclone III or
Cyclone III LS
Device
Cyclone III Device
Nios Processor or User
Logic
Nios Processor or User
Logic
Serial Configuration Device
Supported Parallel Flash
1
Remote system upgrade only supports single-device configuration.
When using remote system upgrade in Cyclone III devices, you must set the mode
select pins (MSEL
[3.0])
to the AS or AP configuration scheme. When using remote
system upgrade in Cyclone III LS devices, you must set
MSEL [3..0]
to the AS
configuration scheme. The MSEL pin setting in remote system upgrade mode is the
same as standard configuration mode. Standard configuration mode refers to normal
Cyclone III device family configuration mode with no support for remote system
upgrades, and the remote system upgrade circuitry is disabled. When using remote
system upgrade in Cyclone III device family, you must enable the
remote update
mode
option setting in the Quartus II software. For more information, refer to
Enabling Remote Update
You can enable or disable remote update for Cyclone III device family in the
Quartus II software before design compilation (in the Compiler Settings menu). To
enable remote update in the compiler settings of the project, perform the following
steps in the Quartus II software:
1. On the Assignments menu, click
Device.
The
Settings
dialog box appears.
2. Click
Device and Pin Options.
The
Device and Pin Options
dialog box appears.
3. Click the
Configuration
tab.
4. From the
Configuration Mode
list, select
Remote.
5. Click
OK.
6. In the
Settings
dialog box, click
OK.
Cyclone III Device Handbook
Volume 1
August 2012 Altera Corporation