欢迎访问ic37.com |
会员登录 免费注册
发布采购

EP3C16Q164C6ES 参数 Datasheet PDF下载

EP3C16Q164C6ES图片预览
型号: EP3C16Q164C6ES
PDF下载: 下载PDF文件 查看货源
内容描述: 的Cyclone III器件手册 [Cyclone III Device Handbook]
分类和应用:
文件页数/大小: 274 页 / 7308 K
品牌: ALTERA [ ALTERA CORPORATION ]
 浏览型号EP3C16Q164C6ES的Datasheet PDF文件第220页浏览型号EP3C16Q164C6ES的Datasheet PDF文件第221页浏览型号EP3C16Q164C6ES的Datasheet PDF文件第222页浏览型号EP3C16Q164C6ES的Datasheet PDF文件第223页浏览型号EP3C16Q164C6ES的Datasheet PDF文件第225页浏览型号EP3C16Q164C6ES的Datasheet PDF文件第226页浏览型号EP3C16Q164C6ES的Datasheet PDF文件第227页浏览型号EP3C16Q164C6ES的Datasheet PDF文件第228页  
9–66  
Chapter 9: Configuration, Design Security, and Remote System Upgrades in the Cyclone III Device Family  
Configuration Features  
Table 9–22 lists the dedicated configuration pins that must be connected properly on  
your board for successful configuration. Some of these pins may not be required for  
your configuration scheme.  
Table 9–22. Dedicated Configuration Pins on Cyclone III Device Family (Part 1 of 4)  
User  
Mode  
Configuration  
Scheme  
Pin Name  
Pin Type  
Description  
4-bit configuration input that sets the Cyclone III device  
family configuration scheme. These pins must be hardwired  
to VCCA or GND. The MSEL[3..0]pins have internal 9-k  
pull-down resistors that are always active.  
MSEL [3..0]  
N/A  
N/A  
All  
All  
Input  
Some of the smaller devices or package options of  
Cyclone III devices do not have the MSEL[3]pin; therefore,  
the AP configuration scheme is not supported.  
Configuration control input. Pulling this pin low with external  
circuitry during user mode causes the Cyclone III device  
family to lose its configuration data, enter a reset state, and  
tri-state all I/O pins. Returning this pin to a logic-high level  
starts a reconfiguration.  
nCONFIG  
Input  
The Cyclone III device family drives nSTATUSlow  
immediately after power-up and releases it after the POR  
time.  
Status output. If an error occurs during configuration,  
nSTATUSis pulled low by the target device.  
Status input. If an external source (for example, another  
Cyclone III device family) drives the nSTATUSpin low  
during configuration or initialization, the target device  
enters an error state.  
Bidirectional  
open-drain  
nSTATUS  
N/A  
All  
Driving nSTATUSlow after configuration and initialization  
does not affect the configured device. If you use a  
configuration device, driving nSTATUSlow causes the  
configuration device to attempt to configure the device, but  
because the device ignores transitions on nSTATUSin user  
mode, the device does not reconfigure. To start a  
reconfiguration, nCONFIGmust be pulled low.  
Status output. The target Cyclone III device family drives  
the CONF_DONEpin low before and during configuration.  
After all configuration data is received without error and  
the initialization cycle starts, the target device releases  
CONF_DONE.  
Bidirectional Status input. After all data is received and CONF_DONE  
CONF_DONE  
N/A  
All  
open-drain  
goes high, the target device initializes and enters user  
mode. The CONF_DONEpin must have an external 10-k  
pull-up resistor in order for the device to initialize.  
Driving CONF_DONElow after configuration and initialization  
does not affect the configured device. Do not connect bus  
holds or ADC to the CONF_DONEpin.  
Cyclone III Device Handbook  
Volume 1  
August 2012 Altera Corporation