欢迎访问ic37.com |
会员登录 免费注册
发布采购

EP3C16Q144C6N 参数 Datasheet PDF下载

EP3C16Q144C6N图片预览
型号: EP3C16Q144C6N
PDF下载: 下载PDF文件 查看货源
内容描述: 的Cyclone III器件手册 [Cyclone III Device Handbook]
分类和应用:
文件页数/大小: 274 页 / 7308 K
品牌: ALTERA [ ALTERA CORPORATION ]
 浏览型号EP3C16Q144C6N的Datasheet PDF文件第25页浏览型号EP3C16Q144C6N的Datasheet PDF文件第26页浏览型号EP3C16Q144C6N的Datasheet PDF文件第27页浏览型号EP3C16Q144C6N的Datasheet PDF文件第28页浏览型号EP3C16Q144C6N的Datasheet PDF文件第30页浏览型号EP3C16Q144C6N的Datasheet PDF文件第31页浏览型号EP3C16Q144C6N的Datasheet PDF文件第32页浏览型号EP3C16Q144C6N的Datasheet PDF文件第33页  
Chapter 2: Logic Elements and Logic Array Blocks in the Cyclone III Device Family
LE Operating Modes
2–3
In addition to the three general routing outputs, LEs in a LAB have register chain
outputs, which allows registers in the same LAB to cascade together. The register
chain output allows the LUTs to be used for combinational functions and the registers
to be used for an unrelated shift register implementation. These resources speed up
connections between LABs while saving local interconnect resources.
LE Operating Modes
Cyclone III device family LEs operate in the following modes:
Normal mode
Arithmetic mode
LE operating modes use LE resources differently. In each mode, there are six available
inputs to the LE. These inputs include the four data inputs from the LAB local
interconnect, the LE carry-in from the previous LE carry-chain, and the register chain
connection. Each input is directed to different destinations to implement the desired
logic function. LAB-wide signals provide clock, asynchronous clear, synchronous
clear, synchronous load, and clock enable control for the register. These LAB-wide
signals are available in all LE modes.
The Quartus
®
II software automatically chooses the appropriate mode for common
functions, such as counters, adders, subtractors, and arithmetic functions, in
conjunction with parameterized functions such as the library of parameterized
modules (LPM) functions. You can also create special-purpose functions that specify
which LE operating mode to use for optimal performance, if required.
Normal Mode
Normal mode is suitable for general logic applications and combinational functions.
In normal mode, four data inputs from the LAB local interconnect are inputs to a
four-input LUT (Figure
The Quartus II Compiler automatically selects the
carry-in (cin) or the
data3
signal as one of the inputs to the LUT. LEs in normal mode
support packed registers and register feedback.
shows LEs in normal mode.
Figure 2–2. Cyclone III Device Family LEs in Normal Mode
Register Chain
Connection sload
sclear
(LAB
Wide)
(LAB
Wide)
Packed Register Input
Q
data1
data2
data3
cin (from cout
of previous LE)
data4
D
ENA
CLRN
Row, Column, and
Direct Link Routing
Row, Column, and
Direct Link Routing
Four-Input
LUT
clock (LAB
Wide)
ena (LAB
Wide)
aclr (LAB
Wide)
Local Routing
Register Bypass
Register Feedback
Register
Chain Output
December 2011
Altera Corporation
Cyclone III Device Handbook
Volume 1