 浏览型号EP2C70A15F324I7ES的Datasheet PDF文件第99页浏览型号EP2C70A15F324I7ES的Datasheet PDF文件第100页浏览型号EP2C70A15F324I7ES的Datasheet PDF文件第101页浏览型号EP2C70A15F324I7ES的Datasheet PDF文件第102页浏览型号EP2C70A15F324I7ES的Datasheet PDF文件第104页浏览型号EP2C70A15F324I7ES的Datasheet PDF文件第105页浏览型号EP2C70A15F324I7ES的Datasheet PDF文件第106页浏览型号EP2C70A15F324I7ES的Datasheet PDF文件第107页  
DC Characteristics and Timing Specifications  
Table 5–13 shows the Cyclone II device pin capacitance for different I/O  
pin types.  
Table 5–13. Device Capacitance Note (1)  
Symbol  
Parameter  
Typical  
Unit  
pF  
CIO  
Input capacitance for user I/O pin.  
6
6
CLVDS  
CVREF  
CCLK  
Input capacitance for dual-purpose  
LVDS/user I/O pin.  
pF  
21  
5
pF  
pF  
Input capacitance for dual-purpose VREF  
pin when used as VREFor user I/O pin.  
Input capacitance for clock pin.  
Note to Table 5–13:  
(1) Capacitance is sample-tested only. Capacitance is measured using time-domain  
reflectometry (TDR). Measurement accuracy is within 0.5 pF.  
You can calculate the power usage for your design using the PowerPlay  
Early Power Estimator and the PowerPlay Power Analyzer feature in the  
Quartus® II software.  
Power  
Consumption  
The interactive PowerPlay Early Power Estimator is typically used  
during the early stages of FPGA design, prior to finalizing the project, to  
get a magnitude estimate of the device power. The Quartus II software  
PowerPlay Power Analyzer feature is typically used during the later  
stages of FPGA design. The PowerPlay Power Analyzer also allows you  
to apply test vectors against your design for more accurate power  
consumption modeling.  
In both cases, only use these calculations as an estimation of power, not  
as a specification. For more information on PowerPlay tools, refer to the  
PowerPlay Early Power Estimator User Guide and the Power Estimation and  
Analysis section in volume 3 of the Quartus II Handbook.  
1
You can obtain the Excel-based PowerPlay Early Power  
Estimator at www.altera.com. Refer to Table 5–3 on page 5–3 for  
typical ICC standby specifications.  
The power-up current required by Cyclone II devices does not exceed the  
maximum static current. The rate at which the current increases is a  
function of the system power supply. The exact amount of current  
consumed varies according to the process, temperature, and power ramp  
rate. The duration of the ICCINT power-up requirement depends on the  
VCCINT voltage supply rise time.  