 浏览型号EP1SGX40GF1020I6的Datasheet PDF文件第148页浏览型号EP1SGX40GF1020I6的Datasheet PDF文件第149页浏览型号EP1SGX40GF1020I6的Datasheet PDF文件第150页浏览型号EP1SGX40GF1020I6的Datasheet PDF文件第151页浏览型号EP1SGX40GF1020I6的Datasheet PDF文件第153页浏览型号EP1SGX40GF1020I6的Datasheet PDF文件第154页浏览型号EP1SGX40GF1020I6的Datasheet PDF文件第155页浏览型号EP1SGX40GF1020I6的Datasheet PDF文件第156页  
PLLs & Clock Networks  
Figure 4–53. Dynamically Programmable Counters & Delays in Stratix GX Device Enhanced PLLs  
Counters and Clock  
Delay Settings are  
Programmable  
All Output Counters and  
Clock Delay Settings can  
be Programmed Dynamically  
Charge  
Pump  
Loop  
Filter  
f
÷n  
Δt  
÷g  
Δt  
PFD  
VCO  
REF  
scandata  
scanclk  
÷m  
Δt  
scanaclr  
÷l  
Δt  
÷e  
Δt  
PLL reconfiguration data is shifted into serial registers from the logic  
array or external devices. The PLL input shift data uses a reference input  
shift clock. Once the last bit of the serial chain is clocked in, the register  
chain is synchronously loaded into the PLL configuration bits. The shift  
circuitry also provides an asynchronous clear for the serial registers.  
Programmable Bandwidth  
You have advanced control of the PLL bandwidth using the  
programmable control of the PLL loop characteristics, including loop  
filter and charge pump. The PLL’s bandwidth is a measure of its ability to  
track the input clock and jitter. A high-bandwidth PLL can quickly lock  
onto a reference clock and react to any changes in the clock. It also allows  
a wide band of input jitter spectrum to pass to the output. A  
low-bandwidth PLL takes longer to lock, but it attenuates all  
high-frequency jitter components. The Quartus II software can adjust  
PLL characteristics to achieve the desired bandwidth. The programmable  
bandwidth is tuned by varying the charge pump current, loop filter  
resistor value, high frequency capacitor value, and m counter value. You  
can manually adjust these values if desired. Bandwidth is programmable  
from 150 kHz to 2 MHz.  