ACEX 1K Programmable Logic Device Family Data Sheet
Column-to-IOE Connections
When an IOE is used as an input, it can drive up to two separate column
channels. When an IOE is used as an output, the signal is driven by a
multiplexer that selects a signal from the column channels. Two IOEs
connect to each side of the column channels. Each IOE can be driven by
column channels via a multiplexer. The set of column channels is different
for each IOE (see Figure 17).
Figure 17. ACEX 1K Column-to-IOE Connections
Note (1)
Each IOE is driven by
a m-to-1 multiplexer
IOE1
m
Column
Interconnect
n
n
n
IOE1
m
Each IOE can drive two
column channels.
Note:
(1) The values for m and n are shown in Table 9.
Table 9 lists the ACEX 1K column-to-IOE interconnect resources.
Table 9. ACEX 1K Column-to-IOE Interconnect Resources
Device
Channels per Column (n) Column Channels per Pin (m)
EP1K10
24
24
24
24
16
16
16
16
EP1K30
EP1K50
EP1K100
34
Altera Corporation