Cyclone Device Handbook, Volume 1
Table 4–2. Cyclone Device Recommended Operating Conditions (Part 2 of 2)
Symbol
Parameter
Conditions
Minimum
Maximum
VCCIO
Unit
V
VO
TJ
Output voltage
Operating junction temperature
0
0
For commercial
use
85
° C
For industrial use
–40
–40
100
125
° C
° C
For extended-
temperature use
Table 4–3. Cyclone Device DC Operating Conditions
Note (6)
Typica
l
Symbol
Parameter
Conditions
Minimum
Maximum Unit
II
Input pin leakage current
VI = VCCIOmax to 0 V (8)
VO = VCCIOmax to 0 V (8)
–10
–10
10
10
μA
μA
IOZ
Tri-stated I/O pin leakage
current
ICC0
VCC supply current (standby)
(All M4K blocks in power-down
mode) (7)
EP1C3
EP1C4
EP1C6
EP1C12
EP1C20
4
6
mA
mA
mA
mA
mA
6
8
12
RCONF (9) Value of I/O pin pull-up resistor VI = 0 V; VCCI0 = 3.3 V
15
20
30
50
25
45
65
100
1
50
70
kΩ
kΩ
kΩ
kΩ
kΩ
before and during configuration
VI = 0 V; VCCI0 = 2.5 V
VI = 0 V; VCCI0 = 1.8 V
VI = 0 V; VCCI0 = 1.5 V
100
150
2
Recommended value of I/O pin
external pull-down resistor
before and during configuration
Table 4–4. LVTTL Specifications (Part 1 of 2)
Symbol
Parameter
Output supply voltage
High-level input voltage
Low-level input voltage
Conditions
Minimum
3.0
Maximum
Unit
VCCIO
3.6
4.1
0.7
V
V
V
VIH
VIL
1.7
–0.5
4–2
Preliminary
Altera Corporation
January 2007