5–32  
Chapter 5: Clock Networks and PLLs in the Cyclone III Device Family  
PLL Reconfiguration  
Table 5–9. Dynamic Phase Shifting Control Signals (Part 2 of 2)  
Signal Name  
Description  
Source  
Destination  
PLL  
reconfiguration  
circuit  
Logic array or I/O  
pins  
PHASESTEP  
SCANCLK  
Logic high enables dynamic phase shifting.  
Free running clock from core used in  
combination with PHASESTEPto enable or  
disable dynamic phase shifting. Shared with  
SCANCLKfor dynamic reconfiguration.  
PLL  
reconfiguration  
circuit  
GCLK or I/O pins  
When asserted, it indicates to core logic that  
the phase adjustment is complete and PLL is  
ready to act on a possible second adjustment  
pulse. Asserts based on internal PLL timing.  
PLL reconfiguration Logic array or  
circuit I/O pins  
PHASEDONE  
Deasserts on rising edge of SCANCLK  
.
Table 5–10 lists the PLL counter selection based on the corresponding  
PHASECOUNTERSELECTsetting.  
Table 5–10. Phase Counter Select Mapping  
PHASECOUNTERSELECT [2]  
[1]  
0
[0]  
0
Selects  
0
0
0
0
1
1
1
All Output Counters  
M Counter  
0
1
1
0
C0 Counter  
C1 Counter  
C2 Counter  
C3 Counter  
C4 Counter  
1
1
0
0
0
1
1
0
To perform one dynamic phase shift step, you must perform the following  
procedures:  
1. Set PHASEUPDOWNand PHASECOUNTERSELECTas required.  
2. Assert PHASESTEPfor at least two SCANCLKcycles. Each PHASESTEPpulse allows one  
phase shift.  
3. Deassert PHASESTEPafter PHASEDONEgoes low.  
4. Wait for PHASEDONEto go high.  
5. Repeat steps 1 through 4 as many times as required to perform multiple phase-  
shifts.  
PHASEUPDOWNand PHASECOUNTERSELECTsignals are synchronous to SCANCLKand must  
meet the tsu and th requirements with respect to the SCANCLKedges.  
1
You can repeat dynamic phase-shifting indefinitely. For example, in a design where  
the VCO frequency is set to 1,000 MHz and the output clock frequency is set to  
100 MHz, performing 40 dynamic phase shifts (each one yields 125 ps phase shift)  
results in shifting the output clock by 180, in other words, a phase shift of 5 ns.  
Cyclone III Device Handbook  