欢迎访问ic37.com |
会员登录 免费注册
发布采购

DPCLK10 参数 Datasheet PDF下载

DPCLK10图片预览
型号: DPCLK10
PDF下载: 下载PDF文件 查看货源
内容描述: 的Cyclone III器件手册 [Cyclone III Device Handbook]
分类和应用:
文件页数/大小: 274 页 / 7302 K
品牌: ALTERA [ ALTERA CORPORATION ]
 浏览型号DPCLK10的Datasheet PDF文件第166页浏览型号DPCLK10的Datasheet PDF文件第167页浏览型号DPCLK10的Datasheet PDF文件第168页浏览型号DPCLK10的Datasheet PDF文件第169页浏览型号DPCLK10的Datasheet PDF文件第171页浏览型号DPCLK10的Datasheet PDF文件第172页浏览型号DPCLK10的Datasheet PDF文件第173页浏览型号DPCLK10的Datasheet PDF文件第174页  
9–12  
Chapter 9: Configuration, Design Security, and Remote System Upgrades in the Cyclone III Device Family  
Configuration Features  
(1)  
Table 9–7. Cyclone III Device Family Configuration Schemes  
Configuration Scheme  
(Part 2 of 2)  
MSEL  
Configuration Voltage Standard (V)  
(2), (3)  
3
2
1
0
Active Parallel ×16 Fast (AP Fast POR, for  
Cyclone III devices only)  
0
1
1
0
1.8  
Passive Serial Standard (PS Standard POR)  
Passive Serial Fast (PS Fast POR)  
0
1
1
0
1
1
0
0
1
0
0
0
3.3/3.0/2.5  
3.3/3.0/2.5  
3.3/3.0/2.5  
(4)  
Fast Passive Parallel Fast (FPP Fast POR)  
Fast Passive Parallel Fast (FPP Fast POR)  
(for Cyclone III devices only) (4)  
1
0
1
0
1
0
1
1
1.8/1.5  
1.8/1.5  
Fast Passive Parallel Fast (FPP Fast POR)  
(for Cyclone III LS devices only)  
Fast Passive Parallel Fast (FPP Fast POR)  
with Encryption (for Cyclone III LS  
devices only)  
0
1
0
1
3.3/3.0/2.5  
Fast Passive Parallel Fast (FPP Fast POR)  
with Encryption (for Cyclone III LS  
devices only)  
0
1
1
0
1.8/1.5  
(5)  
(6)  
(6)  
(6)  
(6)  
JTAG-based configuration  
Notes to Table 9–7:  
(1) Altera recommends connecting the MSEL pins to VCCA or GND depending on the MSEL pin settings.  
(2) The configuration voltage standard is applied to the VCCIO supply of the bank in which the configuration pins reside.  
(3) You must follow specific requirements when interfacing Cyclone III device family with 2.5-, 3.0-, and 3.3-V configuration voltage standards. For  
more information about these requirements, refer to “Configuration and JTAG Pin I/O Requirements” on page 9–7.  
(4) FPP configuration is not supported in the Cyclone III E144 device package of Cyclone III devices.  
(5) The JTAG-based configuration takes precedence over other configuration schemes, which means the MSEL pin settings are ignored.  
(6) Do not leave the MSEL pins floating. Connect them to VCCA or GND. These pins support the non-JTAG configuration scheme used in production.  
Altera recommends connecting the MSEL pins to GND if your device is only using the JTAG configuration.  
AS Configuration (Serial Configuration Devices)  
In the AS configuration scheme, Cyclone III device family is configured using a serial  
configuration device. These configuration devices are low-cost devices with  
non-volatile memories that feature a simple four-pin interface and a small form factor.  
These features make serial configuration devices the ideal low-cost configuration  
solution.  
f
For more information about serial configuration devices, refer to the Serial  
Configuration Devices (EPCS1, EPCS4, EPCS16, EPCS64, and EPCS128) Data Sheet  
chapter in volume 2 of the Configuration Handbook.  
In Cyclone III device family, the active master clock frequency runs at a maximum of  
40 MHz, and typically at 30 MHz. Cyclone III device family only work with serial  
configuration devices that support up to 40 MHz.  
Serial configuration devices provide a serial interface to access configuration data.  
During device configuration, Cyclone III device family reads configuration data using  
the serial interface, decompress data if necessary, and configure their SRAM cells. This  
scheme is referred to as the AS configuration scheme because the device controls the  
configuration interface.  
Cyclone III Device Handbook  
Volume 1  
August 2012 Altera Corporation