欢迎访问ic37.com |
会员登录 免费注册
发布采购

DPCLK0 参数 Datasheet PDF下载

DPCLK0图片预览
型号: DPCLK0
PDF下载: 下载PDF文件 查看货源
内容描述: 的Cyclone III器件手册 [Cyclone III Device Handbook]
分类和应用:
文件页数/大小: 274 页 / 7302 K
品牌: ALTERA [ ALTERA CORPORATION ]
 浏览型号DPCLK0的Datasheet PDF文件第231页浏览型号DPCLK0的Datasheet PDF文件第232页浏览型号DPCLK0的Datasheet PDF文件第233页浏览型号DPCLK0的Datasheet PDF文件第234页浏览型号DPCLK0的Datasheet PDF文件第236页浏览型号DPCLK0的Datasheet PDF文件第237页浏览型号DPCLK0的Datasheet PDF文件第238页浏览型号DPCLK0的Datasheet PDF文件第239页  
Chapter 9: Configuration, Design Security, and Remote System Upgrades in the Cyclone III Device Family  
9–77  
Remote System Upgrade  
Configuration Image Types  
When using remote system upgrade, Cyclone III device family configuration  
bitstreams are classified as factory configuration images or application configuration  
images. An image, also referred to as a configuration, is a design loaded into the  
device that performs certain user-defined functions. Each device in your system  
requires one factory image with the addition of one or more application images. The  
factory image is a user-defined fall-back, or safe, configuration and is responsible for  
administering remote updates with dedicated circuitry. Application images  
implement user-defined functionality in the target Cyclone III device family. You can  
include the default application image functionality in the factory image.  
Remote System Upgrade Mode  
In remote update mode, the Cyclone III device family loads the factory configuration  
image after power-up. The user-defined factory configuration determines which  
application configuration is to be loaded and triggers a reconfiguration cycle. The  
factory configuration can also contain application logic.  
When used with configuration memory, remote update mode allows an application  
configuration to start at any flash sector boundary. Additionally, the remote update  
mode features a user watchdog timer that can detect functional errors in an  
application configuration.  
Remote Update Mode  
When a Cyclone III device family is first powered up in remote update in the AS  
configuration scheme, it loads the factory configuration located at address  
boot_address[23:0] = 24b'0. Altera recommends storing the factory configuration  
image for your system at boot address 24b'0when using the AS configuration  
scheme. A factory configuration image is a bitstream for Cyclone III device family in  
your system that is programmed during production and is the fall-back image when  
an error occurs. This image is stored in non-volatile memory and is never updated or  
modified using remote access. This corresponds to the start address location 0x000000  
in the serial configuration device.  
When you use the AP configuration in Cyclone III devices, the Cyclone III device  
loads the default factory configuration located at the following address after device  
power-up in remote update mode:  
boot_address[23:0] = 24'h010000 = 24'b1 0000 0000 0000 0000  
You can change the default factory configuration address to any desired address using  
the APFC_BOOT_ADDR JTAG instruction. The factory configuration image is stored in  
non-volatile memory and is never updated or modified using remote access. This  
corresponds to the default start address location 0x010000 represented in 16-bit word  
addressing (or the updated address if the default address is changed) in the  
supported parallel flash memory. For more information about the application of the  
APFC_BOOT_ADDRJTAG instruction in AP configuration scheme, refer to “JTAG  
Instructions” on page 9–60.  
August 2012 Altera Corporation  
Cyclone III Device Handbook  
Volume 1  
 复制成功!