Chapter 9: Configuration, Design Security, and Remote System Upgrades in the Cyclone III Device Family  
9–61  
Configuration Features  
I/O Reconfiguration  
Use the CONFIG_IOinstruction to reconfigure the I/O configuration shift register  
(IOCSR) chain. This instruction allows you to perform board-level testing prior to  
configuring the Cyclone III device family or waiting for a configuration device to  
complete configuration. After the configuration is interrupted and JTAG testing is  
complete, the part must be reconfigured using the PULSE_NCONFIG JTAG instruction  
or by pulsing the nCONFIGpin low.  
You can issue the CONFIG_IOinstruction any time during user mode. The CONFIG_IO  
instruction cannot be issued when nCONFIGpin is asserted low (during power up) or  
immediately after issuing a JTAG instruction that triggers reconfiguration. For more  
information about the wait-time for issuing the CONFIG_IOinstruction, refer to  
Table 9–18.  
When using CONFIG_IOinstruction, you must meet the following timing restrictions:  
CONFIG_IOinstruction cannot be issued during the nCONFIGpin low  
Observe 230 s minimum wait time after any of the following conditions are met:  
nCONFIGpin goes high  
Issuing the PULSE_NCONFIGinstruction  
Issuing the ACTIVE_ENGAGEinstruction, before issuing the CONFIG_IOinstruction  
Wait 230 s after power up with nCONFIGpin high before issuing the CONFIG_IO  
instruction (or wait for the nSTATUSpin to go high)  
Table 9–18. Wait Time for Issuing the CONFIG_IO Instruction  
Wait Time  
Time  
Wait time after the nCONFIG pin is released  
230 s  
Wait time after PULSE_NCONFIGor ACTIVE_ENGAGEis  
issued  
230 s  
Use the ACTIVE_DISENGAGEinstruction with CONFIG_IOinstruction to interrupt  
configuration. Table 9–19 lists the sequence of instructions to use for various  
CONFIG_IOusage scenarios.  
(1)  
Table 9–19. JTAG CONFIG_IO (without JTAG_PROGRAM) Instruction Flows  
(Part 1 of 2)  
Configuration Scheme and Current State of the Cyclone III Device Family  
Prior to User Mode  
(Interrupting  
User Mode  
Power Up  
JTAG Instruction  
Configuration)  
AP  
AP  
AP  
PS FPP  
AS  
PS  
FPP  
AS  
PS FPP AS  
(4)  
(4)  
(4)  
FACTORY  
NA  
O
NA  
O
NA  
O
NA  
O
NA  
O
NA  
O
NA  
O
NA  
O
R
R
R
NA  
ACTIVE_DISENGAGE  
CONFIG_IO  
R
R
R
R
R
R
R
R
NA NA NA NA  
JTAG Boundary Scan Instructions (no  
O
O
O
O
O
O
O
O
JTAG_PROGRAM  
)
August 2012 Altera Corporation  
Cyclone III Device Handbook  
Volume 1  
 复制成功!