Digital Signal Processing Block
Table 2–5 shows the number of DSP blocks in each Stratix II device.
Table 2–5. DSP Blocks in Stratix II Devices Note (1)
Total 9 × 9
Multipliers
Total 18 × 18
Multipliers
Total 36 × 36
Multipliers
Device
DSP Blocks
EP2S15
EP2S30
EP2S60
EP2S90
EP2S130
EP2S180
12
16
36
48
63
96
96
48
64
12
16
36
48
63
96
128
288
384
504
768
144
192
252
384
Note to Table 2–5:
(1) Each device has either the numbers of 9 × 9-, 18 × 18-, or 36 × 36-bit multipliers
shown. The total number of multipliers for each device is not the sum of all the
multipliers.
DSP block multipliers can optionally feed an adder/subtractor or
accumulator in the block depending on the configuration. This makes
routing to ALMs easier, saves ALM routing resources, and increases
performance, because all connections and blocks are in the DSP block.
Additionally, the DSP block input registers can efficiently implement shift
registers for FIR filter applications, and DSP blocks support Q1.15 format
rounding and saturation.
Figure 2–28 shows the top-level diagram of the DSP block configured for
18 × 18-bit multiplier mode.
2–42
Stratix II Device Handbook, Volume 1
Altera Corporation