AV-51002
2017.02.10
1-10
DC Characteristics
Symbol
Description
Condition
Minimum(7)
Typical
Maximum(7)
Unit
VCC_AUX_SHARED
HPS
—
2.375
2.5
2.625
V
auxiliary
power
supply
Related Information
Recommended Operating Conditions on page 1-4
Provides the steady-state voltage values for the FPGA portion of the device.
DC Characteristics
Supply Current and Power Consumption
Altera offers two ways to estimate power for your design—the Excel-based Early Power Estimator (EPE) and the Quartus® Prime PowerPlay Power
Analyzer feature.
Use the Excel-based EPE before you start your design to estimate the supply current for your design. e EPE provides a magnitude estimate of the
device power because these currents vary greatly with the resources you use.
e Quartus Prime PowerPlay Power Analyzer provides better quality estimates based on the specifics of the design afer you complete place-and-
route. e PowerPlay Power Analyzer can apply a combination of user-entered, simulation-derived, and estimated signal activities that, when
combined with detailed circuit models, yields very accurate power estimates.
Related Information
•
PowerPlay Early Power Estimator User Guide
Provides more information about power estimation tools.
PowerPlay Power Analysis chapter, Quartus Prime Handbook
Provides more information about power estimation tools.
•
(7)
e power supply value describes the budget for the DC (static) power supply tolerance and does not include the dynamic tolerance requirements.
Refer to the PDN tool for the additional budget for the dynamic tolerance requirements.
Arria V GX, GT, SX, and ST Device Datasheet
Send Feedback
Altera Corporation