 浏览型号5AGXFB3H4F35I5N的Datasheet PDF文件第7页浏览型号5AGXFB3H4F35I5N的Datasheet PDF文件第8页浏览型号5AGXFB3H4F35I5N的Datasheet PDF文件第9页浏览型号5AGXFB3H4F35I5N的Datasheet PDF文件第10页浏览型号5AGXFB3H4F35I5N的Datasheet PDF文件第12页浏览型号5AGXFB3H4F35I5N的Datasheet PDF文件第13页浏览型号5AGXFB3H4F35I5N的Datasheet PDF文件第14页浏览型号5AGXFB3H4F35I5N的Datasheet PDF文件第15页  
Electrical Characteristics  
Page 9  
OCT Specifications  
If you enable on-chip termination (OCT) calibration, calibration is automatically  
performed at power up for I/Os connected to the calibration block.  
Table 8 lists the Arria V OCT termination calibration accuracy specifications. The OCT  
calibration accuracy is valid at the time of calibration only.  
Table 8. OCT Calibration Accuracy Specifications for Arria V Devices  
Calibration Accuracy  
Symbol  
Description  
Conditions (V)  
Unit  
%
I3, C4  
I5, C5  
C6  
Internal series termination  
with calibration  
(25-Ωsetting)  
V
V
CCIO = 3.0, 2.5, 1.8,  
1.5, 1.2  
25-ΩRS  
50-ΩRS  
15  
15  
15  
15  
15  
Internal series termination  
with calibration  
(50-Ωsetting)  
CCIO = 3.0, 2.5, 1.8,  
1.5, 1.2  
15  
15  
15  
15  
%
Internal series termination  
with calibration  
(34-Ωand 40-Ωsetting)  
VCCIO = 1.5, 1.35,  
1.25, 1.2  
34-Ωand 40-ΩRS  
%
Internal series termination  
with calibration  
(48-Ω, 60-Ω, and 80-Ω  
setting)  
48-Ω, 60-Ω, and  
80-ΩRS  
VCCIO = 1.2  
15  
15  
15  
%
%
Internal parallel  
termination with  
calibration (50-Ωsetting)  
V
CCIO = 2.5, 1.8, 1.5,  
1.2  
50-ΩRT  
–10 to +40 –10 to +40 –10 to +40  
Internal parallel  
termination with  
calibration  
(20-Ω, 30-Ω, 40-Ω,  
60-Ω, and 120-Ωsetting)  
20-Ω, 30-Ω,  
40-Ω,60-Ω, and  
120-ΩRT  
VCCIO = 1.5, 1.35, 1.25 –10 to +40 –10 to +40 –10 to +40  
%
Internal parallel  
termination with  
calibration  
60-Ωand 120-Ω RT  
VCCIO = 1.2  
–10 to +40 –10 to +40 –10 to +40  
%
%
(60-Ωand 120-Ωsetting)  
Internal left shift series  
termination with  
calibration  
VCCIO = 3.0, 2.5, 1.8,  
1.5, 1.2  
25-ΩRS_left_shift  
15  
15  
15  
(25-ΩRS_left_shift setting)  
1
Calibration accuracy for the calibrated on-chip series termination (RS OCT) and  
on-chip parallel termination (RT OCT) are applicable at the moment of calibration.  
When process, voltage, and temperature (PVT) conditions change after calibration,  
the tolerance may change.  
February 2014 Altera Corporation  
Arria V GX, GT, SX, and ST Device Datasheet