1-6
Recommended Operating Conditions
AV-51002
2017.02.10
Symbol
Description
Condition
Minimum
(1)
Typical
Maximum
(1)
Unit
3.3 V
3.0 V
2.5 V
V
CCIO
I/O buffers power supply
1.8 V
1.5 V
1.35 V
1.25 V
1.2 V
V
CCD_FPLL
V
CCA_FPLL
V
I
V
O
T
J
t
RAMP
(4)
PLL digital voltage regulator power
supply
PLL analog voltage regulator power
supply
DC input voltage
Output voltage
Operating junction temperature
Power supply ramp time
—
—
—
—
Commercial
Industrial
Standard POR
Fast POR
3.135
2.85
2.375
1.71
1.425
1.283
1.19
1.14
1.425
2.375
–0.5
0
0
–40
200 µs
200 µs
3.3
3.0
2.5
1.8
1.5
1.35
1.25
1.2
1.5
2.5
—
—
—
—
—
—
3.465
3.15
2.625
1.89
1.575
1.418
1.31
1.26
1.575
2.625
3.6
V
CCIO
85
100
100 ms
4 ms
V
V
V
V
V
V
V
V
V
V
V
V
°C
°C
—
—
(1)
(4)
The power supply value describes the budget for the DC (static) power supply tolerance and does not include the dynamic tolerance requirements.
Refer to the PDN tool for the additional budget for the dynamic tolerance requirements.
This is also applicable to HPS power supply. For HPS power supply, refer to t
RAMP
specifications for standard POR when
HPS_PORSEL
= 0 and t
RAMP
specifications for fast POR when
HPS_PORSEL
= 1.
Arria V GX, GT, SX, and ST Device Datasheet
Altera Corporation