 浏览型号5AGTFB1D427I4N的Datasheet PDF文件第63页浏览型号5AGTFB1D427I4N的Datasheet PDF文件第64页浏览型号5AGTFB1D427I4N的Datasheet PDF文件第65页浏览型号5AGTFB1D427I4N的Datasheet PDF文件第66页浏览型号5AGTFB1D427I4N的Datasheet PDF文件第68页浏览型号5AGTFB1D427I4N的Datasheet PDF文件第69页浏览型号5AGTFB1D427I4N的Datasheet PDF文件第70页浏览型号5AGTFB1D427I4N的Datasheet PDF文件第71页  
Chapter 2: Device Datasheet for Arria V Devices  
2–39  
Configuration Specification  
(1)  
Figure 2–5. DCLK-to-DATA[] FPP Configuration Timing Waveform When the Ratio is 1  
tCF2ST1  
tCFG  
tCF2CK  
nCONFIG  
nSTATUS (2)  
tSTATUS  
(6)  
tCF2ST0  
tCLK  
CONF_DONE (3)  
t
CH tCL  
tCF2CD  
tST2CK  
(4)  
DCLK  
tDH  
Word 0 Word 1 Word 2 Word 3  
Word n  
DATA[15..0](5)  
Word n-2 Word n-1  
User Mode  
User Mode  
tDSU  
High-Z  
User I/O  
(7)  
INIT_DONE  
tCD2UM  
Notes to Figure 2–5:  
(1) The beginning of this waveform shows the device in user mode. In user mode, nCONFIG  
, nSTATUS, and CONF_DONEare at logic-high levels. When  
nCONFIGis pulled low, a reconfiguration cycle begins.  
(2) After power up, the Arria V device holds nSTATUSlow for the time of the POR delay.  
(3) After power up, before and during configuration, CONF_DONEis low.  
(4) Do not leave DCLKfloating after configuration. You can drive it high or low, whichever is more convenient.  
(5) For FPP x16, use DATA[15..0]. For FPP x8, use DATA[7..0]. DATA[15..0]are available as a user I/O pin after configuration. The state of this  
pin depends on the dual-purpose pin settings.  
(6) To ensure a successful configuration, send the entire configuration data to the Arria V device. CONF_DONEis released high when the Arria V device  
receives all the configuration data successfully. After CONF_DONEgoes high, send two additional falling edges on DCLKto begin initialization and  
enter user mode.  
(7) After the option bit to enable the INIT_DONEpin is configured into the device, the INIT_DONE goes low.  
February 2012 Altera Corporation  