欢迎访问ic37.com |
会员登录 免费注册
发布采购

1ZU2.5 参数 Datasheet PDF下载

1ZU2.5图片预览
型号: 1ZU2.5
PDF下载: 下载PDF文件 查看货源
内容描述: [Thermal Magnetic Circuit Breaker,]
分类和应用: 电路保护
文件页数/大小: 32 页 / 1762 K
品牌: ALTECH [ ALTECH CORPORATION ]
 浏览型号1ZU2.5的Datasheet PDF文件第7页浏览型号1ZU2.5的Datasheet PDF文件第8页浏览型号1ZU2.5的Datasheet PDF文件第9页浏览型号1ZU2.5的Datasheet PDF文件第10页浏览型号1ZU2.5的Datasheet PDF文件第12页浏览型号1ZU2.5的Datasheet PDF文件第13页浏览型号1ZU2.5的Datasheet PDF文件第14页浏览型号1ZU2.5的Datasheet PDF文件第15页  
E-TRIP  
ONE POLE  
ONE POLE PLUS NEUTRAL  
CHARACTERISTICS  
Application Examples:  
High efficiency motors, which have  
exceedingly high inrush currents.  
Relatively short thermal trip delays  
and very high magnetic trip points.  
Prototype testing is recommended.  
The V-EA-E is the result of continuous  
research and improvement of our G-  
and D-Trip circuit breakers. It  
combines the short thermal trip delay  
of the G-Trip and an even higher  
magnetic trip point than the D-Trip.  
1E  
2EN  
Rated  
Type/  
Type/  
Therefore, the V-EA-E provides  
adequate motor overload and short  
circuit protection.  
Current  
Cat. No.  
Approvals  
Cat. No.  
Approvals  
0.3A  
0.5A  
0.75A  
1EU03  
1EU05  
1EU075  
NA  
1EU1  
1EU1.6  
1EU2  
1EU2.5  
1EU3  
1EU3.5  
1EU4  
1EU5  
1EU6  
U
2ENU03  
2ENU05  
2ENU075  
NA  
2ENU1  
2ENU1.6  
2ENU2  
2ENU2.5  
2ENU3  
2ENU3.5  
2ENU4  
2ENU5  
2ENU6  
U
L
L
U
U
L
L
U
U
L
L
0.8A  
1.0A  
1.6A  
2.0A  
2.5A  
3.0A  
3.5A  
4.0A  
5.0A  
6.0A  
8.0A  
10A  
Type Designation  
U
U
L
L
2
E
N
U
60  
U
U
L
L
U
U
L
L
(a) (b) (c) (d) (e)  
U
U
L
L
U
U
L
L
(a) = Number of Poles  
U
U
L
L
(b) = Trip Characteristic  
(c) = Blank: without neutral pole  
U
U
L
L
U
U
L
L
U
U
L
= N:  
(d) = U:  
= R:  
with neutral pole  
UL/CSA version  
ring tongue terminals,  
UL/CSA version  
L
U
U
L
L
2ENU8  
1EU8  
U
U
L
L
2ENU10  
2ENU12  
2ENU125  
2ENU13  
2ENU15  
2ENU16  
2ENU20  
2ENU25  
2ENU30  
2ENU32  
2ENU40  
2ENU50  
2ENU60  
2EN63  
1EU10  
1EU12  
1EU125  
1EU13  
1EU15  
1EU16  
1EU20  
1EU25  
1EU30  
1EU32  
1EU40  
1EU50  
1EU60  
1E63  
U
U
L
L
12A  
U
U
L
L
12.5A  
13A  
U
U
L
= Blank: European version  
L
U
U
L
L
15A  
16A  
20A  
25A  
30A  
32A  
40A  
50A  
60A  
63A  
(e) = Rated Current  
U
U
L
L
U
U
L
L
U
U
L
L
U
U
L
L
Approvals:  
U
U
L
L
U
U
L
L
U
U
L
L
U
U
L
UL508 Listed  
L
277VAC  
277VAC  
Voltage Rating  
0.3-60A (RC): 10kA with UL-listed  
RK5 back-up fuse or MCCB  
0.3-60A (RC): 10kA with UL-listed  
RK5 back-up fuse or MCCB  
Interrupting Capacity  
(UL/CSA - Ratings)  
0.3-10A (RC): 10kA; 12-60A (RC): 5kA  
no branch circuit protection required  
0.3-10A (RC): 10kA; 12-60A (RC): 5kA  
no branch circuit protection required  
Group Short Circuit  
(UL/CSA - Ratings)  
0.3-63A (RC): 10kA  
0.3-63A (RC): 10kA  
Interrupting Capacity (VDE - Ratings)  
Mechanical Endurance  
10000 ON/OFF operations  
10000 ON/OFF operations  
40°C (104°F)  
40°C (104°F)  
Calibration Temperature  
10/0.3A - 32A = 1.4kg (3.1 lb.)  
40A - 63A = 1.6kg (3.5 lb.)  
5/0.3A - 32A = 1.3kg (2.9 lb.)  
40A - 63A = 1.45kg (3.2 lb.)  
Standard Pack and Weight  
Top: 18-3 AWG; Bottom: 18-2 AWG  
20 lb.in.  
Top: 18-3 AWG; Bottom: 18-2 AWG  
20 lb.in.  
Terminal Size Acceptability  
Terminal Torque  
Basic Dimensions (Elevation View)  
Not European standard rating.  
Please refer to page 21 for specific  
applications.  
DC rating (Manufacturer’s self certification):  
One pole 48VDC, two pole series 125VDC  
91.5 mm  
(3.60 in.)  
91.5 mm  
(3.60 in.)  
17.5 mm (0.69 in.)  
35 mm (1.38 in.)  
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com  