AS7C31026B
®
Recommended operating conditions
Parameter
Symbol
Min
3.0
2.0
–0.5
0
Nominal
Max
Unit
V
Supply voltage
V
3.3
–
3.6
CC
Input voltage
V
V
+ 0.5
CC
V
IH
V
–
0.8
70
85
V
IL
o
commercial
Ambient operating temperature
industrial
T
–
C
A
o
T
–40
–
C
A
VIL = -1.0V for pulse width less than 5ns
V
V
+ 1.5V for pulse width less than 5ns
IH = CC
DC operating characteristics (over the operating range)1
-10
-12
-15
-20
Parameter
Sym
Test conditions
Min Max Min Max Min Max Min Max Unit
Input leakage
current
VCC = Max
VIN = GND to VCC
| ILI
|
–
1
–
1
–
1
–
1
µA
VCC = Max
CE = VIH,
VOUT = GND to VCC
Output leakage
current
| ILO
|
–
1
–
1
–
1
–
1
µA
VCC = Max,
CE ≤ VIL, IOUT = 0mA
f = fMax
Operating power
supply current
ICC
–
–
–
80
30
5
–
–
–
75
25
5
–
–
–
70
20
5
–
–
–
65
20
5
mA
mA
mA
VCC = Max,
CE ≥ VIH, f = fMax
ISB
Standby
power supply
current
VCC = Max, CE ≥ VCC–0.2 V,
VIN ≤ 0.2 V or
ISB1
VIN ≥ VCC–0.2 V, f = 0
VOL
VOH
IOL = 8 mA, VCC = Min
IOH = –4 mA, VCC = Min
–
0.4
–
–
0.4
–
–
0.4
–
–
0.4
–
V
V
Output
voltage
2.4
2.4
2.4
2.4
2
Capacitance (f = 1MHz, T = 25 °C, V = NOMINAL)
a
CC
Parameter
Input capacitance
I/O capacitance
Symbol
Signals
Test conditions
= 0 V
Max Unit
C
A, CE, WE, OE, LB, UB
I/O
V
5
7
pF
pF
IN
IN
C
V
= V
= 0 V
OUT
I/O
IN
3/26/04, v 1.3
Alliance Semiconductor
P. 3 of 10