 浏览型号AS4C8M16SA-6TIN的Datasheet PDF文件第1页浏览型号AS4C8M16SA-6TIN的Datasheet PDF文件第2页浏览型号AS4C8M16SA-6TIN的Datasheet PDF文件第3页浏览型号AS4C8M16SA-6TIN的Datasheet PDF文件第5页浏览型号AS4C8M16SA-6TIN的Datasheet PDF文件第6页浏览型号AS4C8M16SA-6TIN的Datasheet PDF文件第7页浏览型号AS4C8M16SA-6TIN的Datasheet PDF文件第8页浏览型号AS4C8M16SA-6TIN的Datasheet PDF文件第9页  
AS4C8M16SA  
Pin Descriptions  
Table 3. Pin Details  
Symbol  
Type  
Description  
CLK  
Input  
Clock: CLK is driven by the system clock. All SDRAM input signals are sampled on  
the positive edge of CLK. CLK also increments the internal burst counter and  
controls the output registers.  
CKE  
Input  
Clock Enable: CKE activates (HIGH) and deactivates (LOW) the CLK signal. If  
CKE goes low synchronously with clock (set-up and hold time same as other  
inputs), the internal clock is suspended from the next clock cycle and the state of  
output and burst address is frozen as long as the CKE remains low. When all  
banks are in the idle state, deactivating the clock controls the entry to the Power  
Down and Self Refresh modes. CKE is synchronous except after the device enters  
Power Down and Self Refresh modes, where CKE becomes asynchronous until  
exiting the same mode. The input buffers, including CLK, are disabled during  
Power Down and Self Refresh modes, providing low standby power.  
BA0,BA1  
Input  
Bank Activate: BA0, BA1 input select the bank for operation.  
BA1  
0
BA0  
0
Select Bank  
BANK #A  
BANK #B  
BANK #C  
BANK #D  
0
1
1
0
1
1
A0-A11  
Input  
Address Inputs: A0-A11 are sampled during the BankActivate command (row  
address A0-A11) and Read/Write command (column address A0-A8 with A10  
defining Auto Precharge) to select one location out of the 2M available in the  
respective bank. During a Precharge command, A10 is sampled to determine if all  
banks are to be precharged (A10 = HIGH). The address inputs also provide the op-  
code during a Mode Register Set command.  
CS#  
Input  
Input  
Chip Select: CS# enables (sampled LOW) and disables (sampled HIGH) the  
command decoder. All commands are masked when CS# is sampled HIGH. CS#  
provides for external bank selection on systems with multiple banks. It is  
considered part of the command code.  
RAS#  
Row Address Strobe: The RAS# signal defines the operation commands in  
conjunction with the CAS# and WE# signals and is latched at the positive edges of  
CLK. When RAS# and CS# are asserted "LOW" and CAS# is asserted "HIGH,"  
either the BankActivate command or the Precharge command is selected by the  
WE# signal. When the WE# is asserted "HIGH," the BankActivate command is  
selected and the bank designated by BA is turned on to the active state. When the  
WE# is asserted "LOW," the Precharge command is selected and the bank  
designated by BA is switched to the idle state after the precharge operation.  
CAS#  
Input  
Column Address Strobe: The CAS# signal defines the operation commands in  
conjunction with the RAS# and WE# signals and is latched at the positive edges of  
CLK. When RAS# is held "HIGH" and CS# is asserted "LOW," the column access  
is started by asserting CAS# "LOW." Then, the Read or Write command is  
selected by asserting WE# "LOW" or "HIGH."  
Confidential  
4
Rev. 2.2  
Mar /2014