欢迎访问ic37.com |
会员登录 免费注册
发布采购

AS4C4M16SA-6TIN 参数 Datasheet PDF下载

AS4C4M16SA-6TIN图片预览
型号: AS4C4M16SA-6TIN
PDF下载: 下载PDF文件 查看货源
内容描述: [Fully synchronous operation]
分类和应用: 动态存储器光电二极管内存集成电路
文件页数/大小: 55 页 / 1589 K
品牌: ALSC [ ALLIANCE SEMICONDUCTOR CORPORATION ]
 浏览型号AS4C4M16SA-6TIN的Datasheet PDF文件第4页浏览型号AS4C4M16SA-6TIN的Datasheet PDF文件第5页浏览型号AS4C4M16SA-6TIN的Datasheet PDF文件第6页浏览型号AS4C4M16SA-6TIN的Datasheet PDF文件第7页浏览型号AS4C4M16SA-6TIN的Datasheet PDF文件第9页浏览型号AS4C4M16SA-6TIN的Datasheet PDF文件第10页浏览型号AS4C4M16SA-6TIN的Datasheet PDF文件第11页浏览型号AS4C4M16SA-6TIN的Datasheet PDF文件第12页  
AS4C4M16SA-C&I  
Commands  
1
BankActivate  
(RAS# = "L", CAS# = "H", WE# = "H", BAs = Bank, A0-A11 = Row Address)  
The BankActivate command activates the idle bank designated by the BA0, 1 signal. By latching the row  
address on A0 to A11 at the time of this command, the selected row access is initiated. The read or write  
operation in the same bank can occur after a time delay of tRCD(min.) from the time of bank activation. A  
subsequent BankActivate command to a different row in the same bank can only be issued after the  
previous active row has been precharged (refer to the following figure). The minimum time interval  
between successive BankActivate commands to the same bank is defined by tRC(min.). The SDRAM has  
four internal banks on the same chip and shares part of the internal circuitry to reduce chip area; therefore  
it restricts the back-to-back activation of the two banks. tRRD(min.) specifies the minimum time required  
between activating different banks. After this command is used, the Write command and the Block Write  
command perform the no mask write operation.  
T0  
T1  
T2  
T3  
Tn+3 Tn+4  
Tn+5  
Tn+6  
CLK  
Bank A  
Bank A  
Bank B  
Bank A  
ADDRESS  
Row Addr.  
Col Addr.  
Row Addr.  
Row Addr.  
RAS# - CAS# delay(tRCD  
)
RAS# - RAS# delay time(tRRD)  
Bank A  
Activate  
Bank B  
Activate  
Bank A  
Activate  
R/W A with  
AutoPrecharge  
NOP  
NOP  
NOP  
NOP  
COMMAND  
RAS# - Cycle time(tRC  
)
AutoPrecharge  
Begin  
Don’t Care  
Figure 3. BankActivate Command Cycle  
(Burst Length = n)  
2
BankPrecharge command  
(RAS# = "L", CAS# = "H", WE# = "L", BAs = Bank, A10 = "L", A0-A9 and A11 = Don't care)  
The BankPrecharge command precharges the bank designated by BA signal. The precharged bank is  
switched from the active state to the idle state. This command can be asserted anytime after tRAS(min.) is  
satisfied from the BankActivate command in the desired bank. The maximum time any bank can be active  
is specified by tRAS(max.). Therefore, the precharge function must be performed in any active bank within  
tRAS(max.). At the end of precharge, the precharged bank is still in the idle state and is ready to be  
activated again.  
3
4
PrechargeAll command  
(RAS# = "L", CAS# = "H", WE# = "L", BAs = Don’t care, A10 = "H", A0-A9 and A11 = Don't care)  
The PrechargeAll command precharges all banks simultaneously and can be issued even if all banks are  
not in the active state. All banks are then switched to the idle state.  
Read command  
(RAS# = "H", CAS# = "L", WE# = "H", BAs = Bank, A10 = "L", A0-A7 = Column Address)  
The Read command is used to read a burst of data on consecutive clock cycles from an active row in an  
active bank. The bank must be active for at least tRCD(min.) before the Read command is issued. During  
read bursts, the valid data-out element from the starting column address will be available following the  
CAS latency after the issue of the Read command. Each subsequent data-out element will be valid by the  
next positive clock edge (refer to the following figure). The DQs go into high-impedance at the end of the  
burst unless other command is initiated. The burst length, burst sequence, and CAS latency are  
determined by the mode register, which is already programmed. A full-page burst will continue until  
terminated (at the end of the page it will wrap to column 0 and continue.  
Confidential  
7
Rev.3.0  
Mar./2015