1Gb DDR3L AS4C128M8D3L  
- Single-ended requirements for differential signals  
Each individual component of a differential signal (CK, CK#, DQS, DQS#) has also to comply with certain  
requirements for single-ended signals.  
CK and CK# have to approximately reach VSEHmin / VSELmax (approximately equal to the ac-levels (VIH(ac) /  
VIL(ac)) for ADD/CMD signals) in every half-cycle. DQS, DQS# have to reach VSEHmin / VSELmax (approximately  
the ac-levels (VIH(ac) / VIL(ac)) for DQ signals) in every half-cycle proceeding and following a valid transition.  
Note that the applicable ac-levels for ADD/CMD and DQ’s might be different per speed-bin etc. E.g., if  
VIH150(ac)/VIL150(ac) is used for ADD/CMD signals, then these ac-levels apply also for the single-ended signals  
CK and CK#.  
Table 29. Single-ended levels for CK, DQS, CK#, DQS#  
Symbol  
Parameter  
Min.  
Max.  
Unit Note  
Single-ended high level for strobes  
Single-ended high level for CK, CK#  
Single-ended low level for strobes  
Single-ended low level for CK, CK#  
(VDD / 2) + 0.175  
-
V
V
V
V
1~3  
1~3  
1~3  
1~3  
VSEH  
(VDD / 2) + 0.175  
-
-
(VDD / 2) - 0.175  
VSEL  
-
(VDD / 2) - 0.175  
NOTE 1: For CK, CK# use VIH/VIL(ac) of ADD/CMD; for strobes (DQS, DQS#) use VIH/VIL(ac) of DQs.  
NOTE 2: VIH(ac)/VIL(ac) for DQs is based on VREFDQ; VIH(ac)/VIL(ac) for ADD/CMD is based on VREFCA; if a reduced  
ac-high or ac-low level is used for a signal group, then the reduced level applies also here.  
NOTE 3: These values are not defined, however the single-ended signals CK, CK#, DQS, DQS# need to be within the  
respective limits (VIH(dc) max, VIL(dc)min) for single-ended signals as well as the limitations for overshoot and  
undershoot.  
- Differential Input Cross Point Voltage  
To guarantee tight setup and hold times as well as output skew parameters with respect to clock and strobe, each  
cross point voltage of differential input signals (CK, CK# and DQS, DQS#) must meet the requirements in the  
following table. The differential input cross point voltage Vix is measured from the actual cross point of true and  
complete signal to the midlevel between of VDD and VSS.  
Table 30. Cross point voltage for differential input signals (CK, DQS)  
Symbol  
VIX(CK)  
VIX(DQS)  
Parameter  
Min.  
Max.  
Unit Note  
Differential Input Cross Point Voltage  
relative to VDD/2 for CK, CK#  
Differential Input Cross Point Voltage  
relative to VDD/2 for DQS, DQS#  
- 150  
150  
mV  
2
- 150  
150  
mV  
2
NOTE 1: Extended range for Vix is only allowed for clock and if single-ended clock input signals CK and CK# is monotonic  
with a single-ended swing VSEL / VSEH of at least VDD/2 +/-250 mV, and when the differential slew rate of CK -  
CK# is larger than 3 V/ns.  
NOTE 2: The relation between Vix Min/Max and VSEL/VSEH should satisfy following.  
(VDD/2) + Vix (Min) - VSEL 25mV  
VSEH - ((VDD/2) + Vix (Max)) 25mV  