 浏览型号AS4C128M16D3A-12BIN的Datasheet PDF文件第36页浏览型号AS4C128M16D3A-12BIN的Datasheet PDF文件第37页浏览型号AS4C128M16D3A-12BIN的Datasheet PDF文件第38页浏览型号AS4C128M16D3A-12BIN的Datasheet PDF文件第39页浏览型号AS4C128M16D3A-12BIN的Datasheet PDF文件第41页浏览型号AS4C128M16D3A-12BIN的Datasheet PDF文件第42页浏览型号AS4C128M16D3A-12BIN的Datasheet PDF文件第43页浏览型号AS4C128M16D3A-12BIN的Datasheet PDF文件第44页  
AS4C128M16D3A-12BIN  
READ Operation  
z Read Burst Operation  
During a READ or WRITE command DDR3 will support BC4 and BL8 on the fly using address A12 during the  
READ or WRITE (AUTO PRECHARGE can be enabled or disabled).  
A12=0, BC4 (BC4 = burst chop, tCCD=4)  
A12=1, BL8  
A12 will be used only for burst length control, not a column address.  
Figure 16. READ Burst Operation RL=5 (AL=0, CL=5, BL=8)  
T9  
T10  
T0  
T1  
T2  
T3  
T4  
T5  
T6  
T7  
T8  
CK#  
CK  
Notes 3  
READ  
NOP  
NOP  
NOP  
NOP  
NOP  
NOP  
NOP  
NOP  
NOP  
NOP  
COMMAND  
Notes 4  
Bank,  
Col n  
ADDRESS  
tRPRE  
tRPST  
DQS, DQS#  
Notes 2  
Dout  
n
Dout  
n+1  
Dout  
n+2  
Dout  
n+3  
Dout  
n+4  
Dout  
n+5  
Dout  
n+6  
Dout  
n+7  
DQ  
CL = 5  
RL = AL + CL  
NOTES:  
1. BL8, RL = 5, AL = 0, CL = 5.  
2. Dout n = data-out from column n.  
3. NOP commands are shown for ease of illustration; other commands may be valid at these times.  
4. BL8 setting activated by either MR0[A1:0 = 00] or MR0[A1:0 = 01] and A12 = 1 during READ command at T0.  
TRANSITIONING DATA  
Don't Care  
Figure 17. READ Burst Operation RL=9 (AL=4, CL=5, BL=8)  
T0  
T1  
T2  
T3  
T4  
T5  
T6  
T7  
T8  
T9  
T10  
NOP  
CK#  
CK  
Notes 3  
READ  
NOP  
NOP  
NOP  
NOP  
NOP  
NOP  
NOP  
NOP  
NOP  
COMMAND  
Notes 4  
Bank,  
Col n  
ADDRESS  
tRPRE  
DQS, DQS#  
Notes 2  
DQ  
Dout  
n
Dout  
n+1  
Dout  
n+2  
AL = 4  
CL = 5  
RL = AL + CL  
NOTES:  
1. BL8, RL = 9, AL = (CL-1), CL = 5.  
2. Dout n = data-out from column n.  
3. NOP commands are shown for ease of illustration; other commands may be valid at these times.  
TRANSITIONING DATA  
Don't Care  
4. BL8 setting activated by either MR0[A1:0 = 00] or MR0[A1:0 = 01] and A12 = 1 during READ command at T0.  