GaAs 50 dB IC Voltage Variable
Dual Control Attenuator DC–3 GHz
AT002N5-11
Features
I
Dual Control Voltages
I
Low Insertion Loss
I
8 Lead Hermetic Surface Mount Package
I
Capable of Meeting MIL-STD
Requirements
5
-11
ORIENTATION
MARK
0.180 (4.57 mm)
SQ. MAX.
0.150
(3.81 mm)
0.017 (0.43 mm)
0.013 (0.33 mm)
0.050
(1.27 mm)
TYP.
0.400 (10.16 mm)
0.380 (9.65 mm)
Description
The AT002N5-11 is a GaAs IC FET absorptive
attenuator. This device provides up to 50 dB variable
attenuation from DC–3 GHz. Attenuation can be
controlled by varying each of the two control bias voltages
from 0 to -5 V. This attenuator is recommended for fast
response AGC circuits in commercial and high reliability
applications.
0.070 (1.78 mm)
0.040 (1.02 mm)
0.075
(1.91 mm)
MAX.
0.006 (0.15 mm)
0.004 (0.10 mm)
0.250 (6.35 mm)
0.200 (5.08 mm)
Electrical Specifications at 25°C
Parameter
1
Insertion
Loss
2
Frequency
4
DC–1.0 GHz
DC–2.0 GHz
DC–3.0 GHz
DC–1.0 GHz
DC–2.0 GHz
DC–3.0 GHz
DC–1.0 GHz
DC–2.0 GHz
DC–3.0 GHz
50
45
40
Min.
Typ.
1.2
1.4
1.7
52
48
42
1.2:1
1.4:1
1.6:1
1.3:1
1.5:1
1.8:1
Max.
1.4
1.8
2.0
Unit
dB
dB
dB
dB
dB
dB
Attenuation Range
VSWR (I/O)
Operating Characteristics at 25°C
Parameter
Switching Characteristics
Condition
Rise, Fall (10/90% or 90/10% RF)
On, Off (50% CTL to 90/10% RF)
Video Feedthru
3
For All Attenuation Levels
V
Low
= 0 to -0.2 V @ 20
µA
Max.
V
High
= -5 V @ 100
µA
Max.
0.5–3 GHz
0.05 GHz
Frequency
Min.
Typ.
10
15
20
0
-3
Max.
Unit
ns
ns
mV
dBm
dBm
Input Power for 1 dB Compression
Control Voltages
1. All measurements made in a 50
Ω
system, unless otherwise specified.
2. Insertion loss changes by 0.003 dB/°C.
3. Video feedthru measured with 1 ns risetime pulse and 500 MHz bandwidth.
4. DC = 300 kHz.
5. See Quality/Reliability section.
Alpha Industries, Inc.
[781] 935-5150
•
Fax
[617] 824-4579
•
Email
sales@alphaind.com
•
www.alphaind.com
Specifications subject to change without notice. 6/00A
1