Two-Hand Control Devices
Zero-Force Touch Buttons
800Z General Purpose
Approximate Dimensions—mm (inches)
40.9
(1.61)
56.9
(2.24)
48.3
(1.90)
22mm
Version
35.1
(1.38)
129.3 (5.09)
Micro Quick
Disconnect
69.9 (2.75)
110.3
(4.34)
40.9
(1.61)
40.9
(1.61)
30mm
22mm
22.4
(0.88)
Version
Version
39.4
(1.55)
Mini Quick
Disconnect
Cable
129.3 (5.09)
General Purpose with Guards
40.9
(1.61)
30mm
Version
22.4
(0.88)
Cable
General Purpose
Typical Wiring Diagram
Electrical Connections: 10...40V DC and 20...30V AC Input Voltage (Relay O utput); 85...264V AC Input Voltage (Relay O utput)
Note: Separate N.O. and N.C. output relays with shared common.
Black (N.O.)
Brown (+) L1
Blue (-) L2
White (N.C.)
Gray (Common)
5 Conductor Cabled (Relay Output) for 800Z-GL_ _ _
Electrical Connections: 10...30V DC Input Voltage (Transistor O utput); 150m A m ax. per circuit output
( - )
( + )
Brown (+) Blue (-)
( - )
( + )
Brown (+) Blue (-)
Load
Load
Black (N.O.)
White (N.C.)
Black (N.O.)
White (N.C.)
Load
Load
4 Conductor Cabled Sinking (NPN)
4 Conductor Cabled Sourcing (NPN)
Applications Details
LED Blink Rate
** ** **
Diagnostic
Description
Power Up
Device touched during power-up. Device will resume 10 seconds after removal of hand.
*** *** ***
Noise Detection
Device detected an unacceptable level of noise (>20V/m). Device will resume once noise
subsides.
**** **** ****
Margin Detection
A conductive film is building up on the sensing surface. Device will resume once cleared.