Safety Isolation System
ElectroGuard
Non Combination Systems
Product Selection: Remote Lockout Station ➊
Catalogue Num ber
Type 4 W atertight Painted Type 4X W atertight Stainless
“System Isolated”
Light Colour
Type 1 General
Purpose Enclosure
Type 12 Dust tight
Enclosure
Steel Enclosure
Steel Enclosure
White
2030-RLSAW
2030-RLSJW
2030-RLSFW
2030-RLSCW
Product Selection: For Outside of North America (see page 12-19 for Ordering Instructions)
3-Phase Max. kW Rating (50Hz)
Catalogue Num ber ➊
IP 54 Motor Control
Am pere
Rating
Centre Type Enclosure
(w/bussing)
(AC-3)
230V
7.5
13
400V
11
500V
11
600V
11
IP 30 Enclosure
2031-C0023P
2031-C0043P
2031-C0085P
2031-C0110P
2031-C0180P
2031-C0210P
2031-C0300P
2031-C0420P
2031*-C0630P
2031*-C0860P
2031*-C1200P
IP 54 Enclosure
2031-C0023H
2031-C0043H
2031-C0085H
2031-C0110H
2031-C0180H
2031-C0210H
2031-C0300H
2031-C0420H
2031*-C0630H
2031*-C0860H
2031*-C1200H
IP 65 Enclosure
2031-C0023W
2031-C0043W
2031-C0085W
2031-C0110W
2031-C0180W
2031-C0210W
2031-C0300W
2031-C0420W
2031*-C0630W
2031*-C0860W
2031*-C1200W
2031-!0023H
2031-!0043H
2031-!0085H
2031-!0110H
2031-!0180H
2031-!0210H
2031-!0300H
2031-!0420H
2031-!0630H
2031-!0860H
2031-!1200H
23
43
22
22
22
85
25
45
45
45
110
180
210
300
420
630
860
1200
32
55
63
100
160
200
300
425
500
600
1043
55
90
110
150
200
300
450
560
888
63
110
160
220
355
500
710
90
132
200
250
391
To order the Tim e Delay feature, add the following Cat. String to the end of the Cat. No. shown in the table:
Factory set 30 second time delay feature:
-1TD
Example: Catalogue Number 2031-C0180H becomes Catalogue Number 2031-C0180H -1TD to include the time delay feature.
* Input Power Feed Catalogue Num ber Code
The Catalogue Number as listed is incomplete. Select an Input Power Feed Code from the table below.
Example: Catalogue Number 2031*-C0630H becomes Catalogue Number 2031T-C0630H for a “Top Feed” input power requirement.
Input Power Feed
Catalogue Num ber Code
Top Feed
T
B
Bottom Feed
! Bussing Designation
The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table.
Example: Catalogue Number 2031-!0085H becomes Catalogue Number 2031-E0085H for “600A Line Side Incoming Bus and Outgoing Power Cables”
bussing designation.
Ty p e o f B u s s i n g ➊
Catalogue Num ber Code
600A Line Side Incoming Bus and Outgoing Power Cables
1200A Line Side Incoming Bus and Outgoing Power Cables
Line Side Incoming Power Cables and 600A Load Side Outgoing Bus
Line Side Incoming Power Cables and 1200A Load Side Outgoing Bus
E
D
H
R
Input Line Voltage Code
The Catalogue Number as listed is incomplete. Select an Input Line Voltage Code from the table below.
Example: Catalogue Number 2031-C0085P becomes Catalogue Number 2031-C0085PN for a 380V 50Hz Input Line Voltage application.
Input Line Voltage
220V 50HZ
380-400V 50Hz
400-415V 50Hz
440V 50Hz 500V 50Hz 550V 50Hz
Voltage Code for Catalogue Number
A
N
G
B
M
C
Product Selection: Remote Lockout Station ➊
Catalogue Num ber
IP 54 Enclosure
2030-RLSHG
“System Isolated” Light Colour
Green
IP 30 Enclosure
2030-RLSPG
IP 65 Enclosure
2030-RLSW G
➊ Safety Isolation Systems rated up through 85A can support a maximum of four (4) Remote Lockout Stations (RLS).
Systems rated from 110A - 1200A can support a maximum of six (6) RLS. If additional RLS are required, order the optional Expansion Module(s) (see page 12-16).
➊ Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine
operator to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the “Off”
position. Consult your local Rockwell Automation sales office for other time settings.
➊ Bus Type: Copper with tin plating. Consult factory for other types of bussing.
12-5