 浏览型号2032-C0085WX-27B的Datasheet PDF文件第1页浏览型号2032-C0085WX-27B的Datasheet PDF文件第2页浏览型号2032-C0085WX-27B的Datasheet PDF文件第3页浏览型号2032-C0085WX-27B的Datasheet PDF文件第5页浏览型号2032-C0085WX-27B的Datasheet PDF文件第6页浏览型号2032-C0085WX-27B的Datasheet PDF文件第7页浏览型号2032-C0085WX-27B的Datasheet PDF文件第8页浏览型号2032-C0085WX-27B的Datasheet PDF文件第9页  
Safety Isolation System
ElectroGuard
Combination Systems with Fusible Disconnect Switch
Product Selection for Outside North America (see page 12-19 for Ordering Instructions)
3-Phase Max. kW Rating
(50Hz)
Ampere
Fuse Clip
Rating
Rating/
(AC-3) 230V 400V 500V 600V Type
630
200
355
450
500
Catalogue Number
IP 54 Motor Control
Centre Type
Enclosure (with
bussing)
2032-!0630H⊗30D
2032-!0630H⊗-31B
2032-!0630H⊗-31D
2032-!0860H⊗-31B
2032-!0860H⊗-32B
2032-!0860H⊗-31D
2032-!1200H⊗-32B
2032-!1200H⊗-31D
IP 30 Enclosure
IP 54 Enclosure
2032*-C0630H⊗-30D
2032*-C0630H⊗-31B
2032*-C0630H⊗-31D
2032*-C0860H⊗-31B
2032*-C0860H⊗-32B
2032*-C0860H⊗-31D
2032*-C1200H⊗-32B
2032*-C1200H⊗-31D
IP 65 Enclosure
2032*-C0630W⊗-30D
2032*-C0630W⊗-31B
2032*-C0630W⊗-31D
2032*-C0860W⊗-31B
2032*-C0860W⊗-32B
2032*-C0860W⊗-31D
2032*-C1200W⊗-32B
2032*-C1200W⊗-31D
630A DIN
2032*-C0630P⊗-30D
800A BS 88
2032*-C0630P⊗-31B
1600A DIN
2032*-C0630P⊗-31D
800A BS 88
2032*-C0860P⊗-31B
860
250
500
560
600
1250A
BS 88
1250A
BS 88
2032*-C0860P⊗-32B
1600A DIN
2032*-C0860P⊗-31D
1200
391
710
888
1043
2032*-C1200P⊗-32B
1600A DIN
2032*-C1200P⊗-31D
To order the Time Delay feature, add the following Cat. String to the end of the Catalogue Number shown in the table:
Factory set 30 second time delay feature:
-1TD
Example:
Catalogue Number
2032-C0180P
-29B
becomes Catalogue Number
2032-C0180P
-29B-1TD
to include the time delay feature.
* Input Power Feed Catalogue Number Code
The Catalogue Number as listed is incomplete. Select an Input Power Feed Code from the table below.
Input Power Feed
Top Feed
Bottom Feed
Catalogue Number Code
T
B
Example:
Catalogue Number
2032*-C0630P
-31B
becomes Catalogue Number
2032T-C0630P
-31B
for a “Top Feed” input power requirement.
Example:
Catalogue Number
2032-
!
0085H
-27D
becomes Catalogue Number
2032-E0085H
-27D
for “600A Line Side Incoming Bus and Outgoing Power
Cables” bussing designation.
Type of Bussing
600A Line Side Incoming Bus and Outgoing Power Cables
1200A Line Side Incoming Bus and Outgoing Power Cables
Line Side Incoming Power Cables and 600A Load Side Outgoing Bus
Line Side Incoming Power Cables and 1200A Load Side Outgoing Bus
Catalogue Number Code
E
D
H
R
!
Bussing Designation
The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table below.
Input Line Voltage Code
The Catalogue Number as listed is incomplete. Select an Input Line Voltage Code from the table below.
Input Line Voltage
Voltage Code for Catalogue Number
220V 50Hz
A
380-400V 50Hz
N
400-415V 50Hz
G
Example:
Catalogue Number
2032-C0085W
-26B
becomes Catalogue Number
2032-C0085WN-26B
for a 380V 50Hz Input Line Voltage application.
440V 50Hz
B
500V 50Hz
M
550V 50Hz
C
Product Selection: Remote Lockout Station
Catalogue Number
“System Isolated” Light Colour
Green
IP 30 Enclosure
2030-RLSPG
IP 54 Enclosure
2030-RLSHG
IP 65 Enclosure
2030-RLSWG
Power fuses are not included with the disconnect switch. Select power fuses in accordance with applicable local codes.
Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine operator
to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the “Off” position.
Consult your local Rockwell Automation sales office for other time settings.
Bus Type: Copper with tin plating. Consult factory for other types of bussing.
Safety Isolation Systems rated up through 85A can support a maximum of four (4) Remote Lockout Stations (RLS).
Systems rated from 110A - 1200A can support a maximum of six (6) RLS. If additional RLS are required, order the optional Expansion Module(s) (see page 12-16).
12-9