 浏览型号2032-X0630HX-30B的Datasheet PDF文件第1页浏览型号2032-X0630HX-30B的Datasheet PDF文件第2页浏览型号2032-X0630HX-30B的Datasheet PDF文件第3页浏览型号2032-X0630HX-30B的Datasheet PDF文件第4页浏览型号2032-X0630HX-30B的Datasheet PDF文件第5页浏览型号2032-X0630HX-30B的Datasheet PDF文件第6页浏览型号2032-X0630HX-30B的Datasheet PDF文件第8页浏览型号2032-X0630HX-30B的Datasheet PDF文件第9页  
Safety Isolation System
ElectroGuard
Optional Features (continued)
Status Communication to a remote PLC (Should be ordered with Safety Isolation System)
This option provides Remote I/O via “Flex” modules. Communication can be via:
• The DeviceNet communication platform, or
• The Remote I/O communication platform.
Note:
The status communication option allows a remote PLC to receive status signals
from the ElectroGuard Safety Isolation System. The ElectroGuard does not accept input
signals through these communication platforms.
Status communication capabilities:
Overall system status,
Status of each Remote Lockout Station,
Status of the Pneumatic Isolation Module (if used),
Status of other optional Safety Input devices.
Note:
Each communication module provides sixteen (16) data points. In determining which Catalogue Number String to specify from the table below,
please keep the following in mind:
Overall system status information requires one (1) data point.
The Pneumatic Isolation Module (if used) requires one (1) data point.
Each Remote Lockout Station used in the application requires one (1) data point.
Each optional Rockwell Automation Safety Input device (i.e. Safety Mat, Light Curtain, E-Stop Station, Proximity Switch, Photo Switch)
requires one (1) data point.
To order the Status Communication to a remote PLC option, add one of the following Catalogue Strings to the Safety
Isolation System Catalogue Number:
Communication Platform
Number of I/O points
16 points
Remote I/O
32 points
48 points
64 points
16 points
DeviceNet
32 points
48 points
64 points
"
Maximum available for units from 23A through 85A.
!
Only available on units from 110A through 1200A.
e.g. Catalogue Number
2031-A0085JB
becomes Catalogue Number
2031-A0085JB-1COM
to indicate an 85A Safety Isolation System that includes 16 points of
Remote I/O for status communication to a remote PLC.
Catalogue Number String
-1COM
-2COM
-3COM"
-4COM!
-1DNET
-2DNET
-3DNET"
-4DNET!
Cover Mounted Metering (Must be ordered with Safety Isolation System):
Cover mounted ammeters and/or voltmeters are available as factory installed options in order to provide visual indication of line side system
current and/or voltage.
To order metering, add one or more of the following Catalogue Strings to the Safety Isolation System Catalogue
Number:
Type of Metering Required
Single-phase Ammeter
Three-phase Ammeter
Single-phase Voltmeter
Three-phase Voltmeter
Catalogue Number String
-1AM
-3AM
-1VM
-3VM
e.g. Catalogue Number
2031-A0085JB
becomes Catalogue Number
2031-A0085JB-1AM
to indicate an 85A Safety Isolation System that includes a cover mounted
single-phase Ammeter.