IEC Load Switches  
Bulletin 194E  
25 Amps to 100 Amps  
Specifications  
Electrical Ratings  
Perform ance Data  
25 A  
32 A  
40 A  
63 A  
80 A  
100 A  
Aux.  
IEC Applications  
Contacts  
Rated operational voltage (U ): IEC ➊  
[V]  
690  
600  
690  
600  
690  
600  
690  
600  
690  
600  
690  
600  
690  
600  
e
Rated operational voltage (U ): UL, CSA  
[V]  
e
Rated insulation voltage (U ): IEC/UL, CSA  
[V]  
690/600 690/600 690/600 690/600 690/600 690/600  
690/600  
8
i
Rated impulse voltage (U ): UL, CSA  
[kV]  
8
8
8
8
8
8
imp  
Te s t vo l tag e , ( U ) 1 minute  
[kV]  
w
2.5  
1.0  
2.5  
1.5  
2.5  
1.6  
2.5  
2.4  
2.5  
3.6  
2.5  
5.5  
2.5  
0.4  
i
Lost power per pole  
[Hz]  
50/60  
50/60  
50/60  
50/60  
50/60  
50/60  
50/60  
Rated frequency  
Conventional free air thermal current I  
[A]  
[A]  
30  
25  
40  
32  
50  
40  
75  
63  
100  
80  
120  
100  
10 ➊  
th  
Conventional enclosed thermal current I  
6
th  
Rated current I ➊  
e
Non inductive or only slightly  
inductive loads  
AC-1/  
[A]  
25  
32  
40  
63  
80  
100  
10  
Switching of resistive loads with  
slight overload  
AC-21A  
Rated power P  
e
230V  
[kW]  
7.5  
7.5  
15  
18.5  
22  
30  
Occasional switching of 3 motors  
and other highly inductive loads  
(criterion for selecting main  
switches)  
AC-23A  
400V  
690V  
[kW]  
[kW]  
11  
11  
15  
15  
18.5  
18.5  
22  
22  
37  
37  
45  
45  
230V  
400V  
690V  
[kW]  
[kW]  
[kW]  
5.5  
7.5  
7.5  
7.5  
11  
11  
11  
15  
15  
15  
18.5  
18.5  
18.5  
30  
22  
22  
37  
22  
Squirrel-cage motors; starting and  
stopping of running motors  
AC-3  
Short circuit current (coordination type 2)  
Rated conditional short-circuit current  
Maximum fuse rating of circuit (type g, G)  
Rated short-time current 1cw, 1s  
400/415V [kA]  
20  
25  
900  
204  
232  
136  
15  
25  
900  
204  
232  
136  
20  
50  
1300  
484  
336  
196  
15  
63  
1300  
484  
336  
196  
30  
80  
2500  
780  
680  
376  
25  
100  
2500  
780  
680  
376  
[A]  
[A]  
230V  
400V  
690V  
[A]  
[A]  
[A]  
Rated breaking capacity AC23A (cosϕ 0.45)  
DC switching capacity  
48V  
[A]  
25  
32  
40  
63  
80  
100  
Rated current I  
e
1-pole  
110V  
220V  
440V  
96V  
110V  
220V  
440V  
600V  
110V  
220V  
440V  
600V  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
6
1
0.5  
25  
23  
5
6
1
0.5  
32  
25  
6
8
10  
15  
0.6  
63  
50  
10  
1.5  
0.8  
63  
28  
3.6  
2
16  
3
0
3
1.5  
0.6  
40  
32  
8
1.5  
0.8  
40  
20  
3.6  
2
0.7  
80  
70  
16  
3
0.7  
100  
80  
20  
3
2-poles  
in  
series  
For resistive loads,  
DC-21A  
T 1 ms  
1
1
U max = 660V  
e
0.6  
25  
13  
22  
1.5  
0.6  
32  
15  
2.2  
0.6  
1
1
80  
50  
6.5  
3
100  
63  
6.5  
3
3-poles  
in  
series  
Rated power P  
e
DC-23A, DC-3, DC-5  
90V  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
1.3  
1.1  
0.9  
0.6  
0.4  
1.5  
1.3  
1.1  
0.6  
0.4  
2.9  
2.2  
1.7  
0.9  
0.5  
4.1  
3.3  
2
0.9  
0.5  
5.1  
5.5  
3.5  
1.1  
0.9  
7.2  
7
4.4  
1.1  
0.9  
3-poles  
in series  
110V  
220V  
440V  
600V  
For inductive loads,  
T 15 ms  
See conformity to standards listed on page.  
Suitable also for SEV 500.  
10-17