1397
Digital DC Drive
380/415V AC Product Selection
1397
Bulletin Number
- U55FN
➊
- HA2
➋
-
Rating Type
(must be specified)
Control Interface
(must be specified)
DS050
AC Line Disconnect
(optional)
-
PE
Pulse Encoder Interface
(optional)
380/415V AC Drives — IP 00 (Open) — No Enclosure
380V AC Input 415V AC Input
kW (Hp)
1.8 (2.4)
9 (12)
17.9 (24)
35.8 (48)
89.5 (120)
kW (Hp)
2.1(2.8)
10.3(13.8)
20.8(27.6)
41.2(55.2)
102.9(138)
Code
U7F__➊
U29F__➊
U55F__➊
U110F__➊
U265F__➊
380/415V AC
400/460V DC Rated 250/270V DC Rated
Rated Line Amps Armature Amps
Field Amps
10
26
48
94
226
7
29
55
110
265
10
10
10
15
20
460V AC Product Selection
1397
Bulletin Number
- B003N
➊
- HA2
➋
-
Rating Type
(must be specified)
Control Interface
(must be specified)
DS050
AC Line Disconnect
(optional)
-
PE
Pulse Encoder Interface
(optional)
Nominal
Drive Rating 460V AC Drives — IP 00 (Open) — No Enclosure
kW (Hp)
➌
2.2 (3)
3.7 (5)
5.5 (7.5)
7.5 (10)
11 (15)
15 (20)
18.5 (25)
22 (30)
30 (40)
37 (50)
45 (60)
56 (75)
75 (100)
93 (125)
112 (150)
149 (200)
187 (250)
224 (300)
298 (400)
373 (500)
448 (600)
Code
B003__➊
B005__➊
B007__➊
B010__➊
B015__➊
B020__➊
B025__➊
B030__➊
B040__➊
B050__➊
B060__➊
B075__➊
B100__➊
B125__➊
B150__➊
B200__➊
B250__➊
B300__➊
B400__➊➏
B500__➊➏
B600__➊➏
460V AC Rated➍ 500VDC Rated➍
Line Amps
Armature Amps
10
12
15
18
24
31
39
45
63
74
86
110
143
177
213
281
351
421
567
680
816
6
10
14
19
27
35
45
52
73
86
100
129
167
207
250
330
412
495
667
800
960
300VDC Rated➎
Field Amps
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
15
15
15
15
15
➊
Either an “N” (non-regenerative) or an “R” (regenerative) drive must be specified.
➋
At least one of either a Human Interface Module (HIM) or Option 1203-GD2 using
DriveTools32™
will be required to program the drive. Chosen option(s) may be ordered factory installed (if
available) or as user installed kits.
➌
kW ratings are based on rated input voltage.
➍
Consult factory for alternate voltages.
➎
For special field voltage requirements refer to the Enhanced Field Supply Option.
➏
Inverting fault protection must be separately supplied external to drive on 400-600 Hp negative.
See user installed option 1397-IFB600.
Allen-Bradley