欢迎访问ic37.com |
会员登录 免费注册
发布采购

AK4685 参数 Datasheet PDF下载

AK4685图片预览
型号: AK4685
PDF下载: 下载PDF文件 查看货源
内容描述: 多通道编解码器的差分模拟I / O [Multi-channel CODEC with Differential Analog I/O]
分类和应用: 解码器编解码器
文件页数/大小: 52 页 / 575 K
品牌: AKM [ ASAHI KASEI MICROSYSTEMS ]
 浏览型号AK4685的Datasheet PDF文件第34页浏览型号AK4685的Datasheet PDF文件第35页浏览型号AK4685的Datasheet PDF文件第36页浏览型号AK4685的Datasheet PDF文件第37页浏览型号AK4685的Datasheet PDF文件第39页浏览型号AK4685的Datasheet PDF文件第40页浏览型号AK4685的Datasheet PDF文件第41页浏览型号AK4685的Datasheet PDF文件第42页  
[AK4685]  
Serial Control Interface  
The AK4685 supports fast-mode I2C-bus system (max: 400kHz).  
1. Data transfer  
All commands are preceded by START condition. After the START condition, a slave address is sent. After the AK4685  
recognizes START condition, the device interfaced to the bus waits for the slave address to be transmitted over the SDA  
line. If the transmitted slave address matches an address for one of the devices, the designated slave device pulls the SDA  
line to LOW (ACKNOWLEDGE). The data transfer is always terminated by STOP condition generated by the master  
device.  
1-1. Data validity  
The data on the SDA line must be stable during the HIGH period of the clock. The HIGH or LOW state of the data line  
can only change when the clock signal on the SCL line is LOW except for the START and the STOP condition.  
SCL  
SDA  
DATA LINE  
STABLE :  
DATA VALID  
CHANGE  
OF DATA  
ALLOWED  
Figure 19. Data Transfer  
1-2. START and STOP condition  
A HIGH to LOW transition on the SDA line while SCL is HIGH indicates START condition. All sequences start from  
START condition. A LOW to HIGH transition on the SDA line while SCL is HIGH defines STOP condition. All  
sequences end by STOP condition.  
SCL  
SDA  
START CONDITION  
STOP CONDITION  
Figure 20. START and STOP conditions  
MS1106-E-00  
2009/08  
- 38 -  
 复制成功!