[AK4160]  
Correction of Environment Drifts  
The Capacitance of a sense terminal is influenced from the hydrothermal condition and the grime of the surface.  
The AK4160 monitors the measurement value continuously. If the value is changed by the environment, “The Noncontact  
Reference Value” is corrected. The reference value is charged very slowly following the measurement value of not  
touched status by the correction circuit. The threshold of touch detection and release detection is synchronized with the  
reference value. In case of the touch detection, the reference value is not followed to the measurement value.  
The increasing rate and the decreasing rate of the reference value can be configured independently. When a finger  
approaches slowly to the touch switch, the measurement value is decreased gradually. The decreasing rate of the reference  
value must be configured slower than the increasing rate to avoid false detection.  
V
V
Touch  
Environmental Drift  
Reference Value  
Release Threshould  
Touch Threshould  
Reference Value  
Measurement Value  
Release Threshould  
Touch Threshould  
Measurement Value  
T
T
Figure 8. The Voltage of Sense Terminal and Automatic Correction of Environmental Drift  
The initial reference value after the reset release can be selected from a user configuration and the automatic  
configuration that configured to 32/32, 31/32, and 30/32 of the first measurement value. (Address 0x70 RIM1-0 bits)  
Debounce  
The touch status is updated when the output of the second filter is judged as touched or released for N times continuously  
for a stabilized touch detection. The count “N” is user-selectable from 0 to 15 times. (Address 0x71 DEBT3-0, DEBR3-0  
bits) The Update rate of the touch status is calculated as follows. “Sampling Rate of Second Filter x Sample Count of  
Second Filter x Debounce Count”  
Automatic Initial Setting  
The capacitance of a sensor is different according to the size and the shape of a touch switch. The charge current and the  
charge period should be configured adequately for optimal sensitivity to every touch switches. (Address 0x45-0x54  
CCn5-0 bits, Address 0x55-0x5C CTn2-0 bits) The AK4160 has the automatic initial calibration that configured to the  
optimal setting. (Address 0x5F ACC)  
External Reset  
The RSTN pin is input terminal for a low-active asynchronous reset with an internal pull-up resistor. A measurement  
operation is aborted and the internal circuit is initialized immediately by the reset. The serial interface transaction is also  
aborted. If the reset is executed in a transaction, an unintended access may occur. Therefore, the reset must be executed  