欢迎访问ic37.com |
会员登录 免费注册
发布采购

AK2573AVB 参数 Datasheet PDF下载

AK2573AVB图片预览
型号: AK2573AVB
PDF下载: 下载PDF文件 查看货源
内容描述: 125M / 156M激光二极管驱动器+ APC [125M / 156M Laser Diode Driver + APC]
分类和应用: 驱动器驱动程序和接口二极管激光二极管接口集成电路PC
文件页数/大小: 38 页 / 266 K
品牌: AKM [ ASAHI KASEI MICROSYSTEMS ]
 浏览型号AK2573AVB的Datasheet PDF文件第19页浏览型号AK2573AVB的Datasheet PDF文件第20页浏览型号AK2573AVB的Datasheet PDF文件第21页浏览型号AK2573AVB的Datasheet PDF文件第22页浏览型号AK2573AVB的Datasheet PDF文件第24页浏览型号AK2573AVB的Datasheet PDF文件第25页浏览型号AK2573AVB的Datasheet PDF文件第26页浏览型号AK2573AVB的Datasheet PDF文件第27页  
ASAHI KASEI  
[AK2573A]  
RE_SFP = 0 operation  
Set “H” when OPTALM, CURRALM, TEMPALM or DATAALM is detected  
Set “L” when no ALM detected.  
RE_SFP=1 operation  
Support TX_FAULT of the SFP (Small Form-factor Pluggable) requirement.  
Set and hold “H” when detected OPTALM, CURRALM, TEMPALM or DATAALM and go into shutdown  
mode.  
Reset to “L” when TXDIS1 or TXDIS2 is “H“ L”. Refer to6. Shutdown” for more information.  
During “Adjustment mode”, TXFAULT detection is ignored.  
6. Shutdown  
6.1 Shutdown Operation  
Fig 6-1 shows the shutdown operation. The AK2573A supports the SFP (Small Form-factor Pluggable) requirement.  
Fig 6-1 Shutdown Operation  
TXDIS1  
TXDIS2  
RE_SFP  
TXFAULT  
Operation  
Shutdown  
Shutdown  
Normal Operation  
Normal Operation  
Shutdown  
Remarks  
Shutdown with pin  
Shutdown with pin  
1
X
0
0
0
X
1
0
0
0
X
X
0
1
1
X
X
X
0
1
SFP TXFAULT  
Operation  
Fig 6-2 Shutdown Condition  
Function Operation  
I-DAC1 / 2 output High-Z (0mA output)  
Remarks  
APC_FF  
APC_FB  
ALM  
Normal Operation.  
Keep the data atshutdown request.  
Normal Operation  
TXFAULT  
R_SFP=0: Normal Operation  
R_SFP=1: Keep the data at shutdown request.  
6.2 Temperature Comparison between Shutdown Request and Release  
The AK2573A keeps the temperature data at shutdown request and compares it with temperature at release request  
to avoid over-current conditions at the LD. When the AK2573A detects a temperature difference between at  
shutdown request and the release request, the APC FB data is set to 0 or to initial values in response to the  
temperature at the release request. Thetemperaturedifference is programmable.  
When the AK2573A does not detecta temperature difference,it keeps the APC FB data, resulting in faster operation.  
This function works at release request as follows:  
if (ABS(R_TEMP_STDW – R_TEMP)) > R_TEMP_WIN)  
R_APC_FB = 0 or reset to the initial value in response to the R_TEMP  
where, R_TEMP_STDW is a temperature at shutdown request  
R_TEMP is a temperature at release request  
R_TEMP_WIN is a temperature difference (user programmable)  
APC FF continues to operate during shutdown for fast performance when arelease request is received. However, the  
I-DAC current stays at 0mA.  
<MS0189-E-01>  
-23-  
2004/5  
 复制成功!