9.4. Description of Each Operation Mode  
9.4.1. Power-down Mode  
Power to almost all internal circuits is turned off. All registers are accessible in Power-down mode. Data  
stored in read/write registers are remained. They can be reset by soft reset.  
9.4.2. Single Measurement Mode  
When Single measurement mode (MODE[4:0] bits = “00001”) is set, magnetic sensor measurement is started.  
After magnetic sensor measurement and signal processing is finished, measurement magnetic data is stored to  
measurement data registers (HXL to HZH), then AK09915 transits to Power-down mode automatically. On  
transition to Power-down mode, MODE[4:0] bits turns to “00000”. At the same time, DRDY bit in ST1  
register turns to “1”. This is called “Data Ready”. When any of measurement data registers (HXL to TMPS) or  
ST2 register is read, DRDY bit turns to “0”. It remains “1” on transition from Power-down mode to another  
mode. DRDY pin is in the same state as DRDY bit. (Figure 9.2)  
When sensor is measuring (Measurement period), measurement data registers (HXL to TMPS) keep the  
previous data. Therefore, it is possible to read out data even in measurement period. Data read out in  
measurement period are previous data. (Figure 9.3)  
Operation Mode:  
Power-down  
Single measuremnet  
(1)  
(2)  
(3)  
Measurement period  
Measurement Data Register  
Last Data  
Measurement Data (1)  
Data(2)  
Data(3)  
DRDY  
Data read  
Data(1)  
Data(3)  
Register Write  
MODE[4:0]="00001"  
MODE[4:0]="00001" MODE[4:0]="00001"  
Figure 9.2 Single measurement mode when data is read out of measurement period  
Operation Mode:  
Power-down  
Single measuremnet  
(1)  
(2)  
(3)  
Measurement period  
Measurement Data Register  
Last Data  
Measurement Data (1)  
Data(3)  
DRDY  
Data read  
Data(1)  
Register Write  
MODE[4:0]="00001"  
MODE[4:0]="00001" MODE[4:0]="00001"  
Figure 9.3 Single measurement mode when data read started during measurement period  