欢迎访问ic37.com |
会员登录 免费注册
发布采购

AT1454B 参数 Datasheet PDF下载

AT1454B图片预览
型号: AT1454B
PDF下载: 下载PDF文件 查看货源
内容描述: 照相闪光灯电容充电器DSC [Photoflash Capacitor Charger for DSC]
分类和应用: 闪光灯
文件页数/大小: 18 页 / 483 K
品牌: AIMTRON [ AIMTRON TECHNOLOGY ]
 浏览型号AT1454B的Datasheet PDF文件第9页浏览型号AT1454B的Datasheet PDF文件第10页浏览型号AT1454B的Datasheet PDF文件第11页浏览型号AT1454B的Datasheet PDF文件第12页浏览型号AT1454B的Datasheet PDF文件第14页浏览型号AT1454B的Datasheet PDF文件第15页浏览型号AT1454B的Datasheet PDF文件第16页浏览型号AT1454B的Datasheet PDF文件第17页  
AT1454/AT1454A/AT1454B  
Preliminary Product Information  
Photoflash Capacitor Charger for DSC  
Vout: Target Output Voltage  
VDS(MAX):Maximum drain to source voltage of NMOS.  
Adjustable Output Voltage  
The AT1454/1454A/B senses output voltage by a voltage divider connecting to output  
terminal. R7 to (R8+R9) ratio determines the output voltage as shown in the  
application circuit Figure 1. The feedback reference voltage is 1.1V. Calculate the  
remaining resistors with following equations:  
R8 + R9  
VOUT =VFB × (1+  
)
R7  
R8and R9 must be greater than 0805 size resistor for enduring secondary HV.  
Rectifying Diode  
The rectifying diode should be low capacitance type with sufficient reverse  
recovery-voltage and forward current ratings. The peak reverse recovery-voltage that  
diode is approximately:  
V
PK-RVOUT + (N x VCC)  
The peak current of the diode is simply:  
PK-SEC= IPK-PRI / N  
I
Primary Inductance  
A fly-back transformer needs to store substantial amounts of energy in the core during  
each switching cycle. The transformer will generally require an air gap. The use of an  
air gap in the core makes the energy storage. While the power switch is off, energy  
transferred to the output capacitor is proportional to the primary inductance for a  
constant primary current. The primary inductance needs to be equal or larger than a  
certain minimum value to ensure that AT1454 series has adequate time to respond to  
the fly-back waveform. The switch off time should be 500ns or larger for the AT1454  
series. The minimum inductance can be calculated with the following formula:  
9  
500×10 ×VOUT  
LPRI  
N × IPK PRI  
Vout: Target Output Voltage  
N: Transformer Turns Ratio  
IPK-PRI: Primary Peak Current  
7F, No.9,PARK AVENUE. II, Science-Based Industrial Park, Hsinchu 300,Taiwan, R.O.C.  
Tel: 886-3-563-0878  
3/24/2006 REV:1.2  
Fax: 886-3-563-0879  
WWW: http://www.aimtron.com.tw  
Email: service@aimtron.com.tw  
13