AT1397A/B
Preliminary Product Information
6-Channel DC-DC Converter for DSC
Absolute Maximum Ratings*1
Rated Value
Min. Max.
Parameter
Symbol
Units
Storage Temperature
TSTG
TOPR
-55
-35
-0.3
-0.3
-0.3
-
150
85
℃
℃
V
Operating Temperature TA
PVCC1,PVCC2,PVCC3,PVCC4 Input Voltage
LX1,LX2, OUT3M,OUT3S Input Voltage
Other Input Pin
6.0
6.0
6.0
2.25
200
2
-
VLX/OUT
V
-
-
V
LX1, LX2 Current
A
OUT3M,OUT3S Current
-
-
mA
KV
V
HBM
MM
Pd
-
ESD Susceptibility*2
-
200
1000
Power Consumption
-
mW
1. Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the
device. These are stress ratings only, and functional operation of the device at these or any other
conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure
to absolute maximum rating conditions for extended periods may affect device reliability.
2. Device are ESD sensitive. Handling precaution recommended. The Human Body model is a 100pF
capacitor discharged through a 1.5KΩ resistor into each pin.
Recommended Operating Conditions
(Ta=+250C)
Value
Typ
Parameter
Symbol
Unit
Min
2.5
2.5
0
Max
5.5
Startup power supply voltage
Power supply voltage
Vcc
PVCC
VIN
--
V
V
--
5.5
Feedback input voltage
Control input voltage
--
Vcc-2
Vcc
1.0
V
VCTL
CSS
0
--
V
Soft start capacitor
--
0.1
0.1
0.1
25
µF
µF
µF
℃
Short Circuit Protection Capacitor
VREG pin capacitor
CSCP
CVREG
--
1.0
0.082
-20
--
T
Operating ambient temperature*
85
A
*Using X5R or X7R input capacitors.
7F, No.9, Park Avenue II, Science-Based Industrial Park, Hsinchu 300,Taiwan, R.O.C.
Tel: 886-3-563-0878
1/10/2006 REV:1.0
Fax: 886-3-563-0879
WWW: http://www.aimtron.com.tw
Email: service@aimtron.com.tw
4