AT1391
Preliminary Product Information
1-Channel Step-Down PWM Controller
Absolute Maximum Ratings
*1
Parameter
Power Supply Voltage
Source Average Current of OUT
Sink Average Current of OUT
Source Peak Current of OUT
Sink Peak Current of OUT
Input Voltage to Error Amplifier
Continuous power dissipation
Operating temperature
Storage temperature
ESD Susceptibility *
2
Condition
—
—
—
—
—
—
TSSOP8(Ta=+25℃)
—
—
HBM
MM
Rated Value
Min.
Max.
-
+7
-
-50
-
50
-
-200
-
200
-
6.5
-
500
-30
+85
-55
+125
2
200
Unit
V
mA
mA
mA
mA
V
mW
0
C
0
C
KV
V
1. Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These
are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in
the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for
extended periods may affect device reliability.
2.
Device are ESD sensitive. Handling precaution recommended. The Human Body model is a 100pF capacitor discharged
through a 1.5KΩ resistor into each pin
Recommended Operating Conditions
(Ta=+25
0
C)
Parameter
Power supply voltage
Control input voltage
Operating temperature
Symbol
V
CC
V
CTL
T
OP
Min.
2.5
0
-20
Values
Typ.
--
--
+25
Max.
6
6
+85
Unit
V
V
°C
7F, No.9, PARK AVENUE II, Science-Based Industrial Park, Hsinchu 300,Taiwan, R.O.C.
Tel: 886-3-563-0878
Fax: 886-3-563-0879
WWW:
http://www.aimtron.com.tw
3/15/2006 REV:1.1
Email:service@aimtron.com.tw
3