Series AMSRL1-78JZ
Up to 12 Watt | DC-DC Switching Regulator
AMSRL1-786.5-JZ
Trim down %
Vout (VDC)
1
2
6.37
3
4
6.24
5
6
6.11
7
8
5.98
9
10
5.85
6.435
6.305
6.175
6.045
5.915
Rt down (KΩ) 3284.64 1717.46 1149.32 855.82 676.58 555.75 468.78 403.18 351.94 310.81
Trim up %
Vout (VDC)
Rt up (KΩ)
1
2
6.63
3
4
6.76
5
6.825
80.03
6
6.89
62.63
7
6.955
50.30
8
7.02
41.10
9
7.085
33.98
10
7.15
28.31
6.565
6.695
553.16 244.37 151.32 106.45
AMSRL1-7809-JZ
Trim down %
Vout (VDC)
1
8.91
2
8.82
3
8.73
4
8.64
5
8.55
6
8.46
7
8.37
8
8.28
9
8.19
10
8.1
Rt down (KΩ) 3190.28 1719.75 1164.39 872.63 692.79 570.83 482.69 416.01 363.80 321.82
Trim up %
Vout (VDC)
Rt up (KΩ)
1
9.09
2
9.18
3
9.27
4
9.36
72.64
5
9.45
52.87
6
9.54
39.93
7
9.63
30.80
8
9.72
24.02
9
9.81
18.78
10
9.9
14.62
433.71 178.60 106.60
AMSRL1-7812-JZ
Trim down %
Vout (VDC)
1
2
3
4
5
11.4
6
7
8
9
10
10.8
11.88
11.76
11.64
11.52
11.28
11.16
11.04
10.92
Rt down (KΩ) 3329.00 1641.50 1079.00 797.75 629.00 516.50 436.14 375.88 329.00 291.50
Trim up %
Vout (VDC)
Rt up (KΩ)
1
2
3
12.36
65.00
4
12.48
46.25
5
12.6
35.00
6
12.72
27.50
7
12.84
22.14
8
12.96
18.13
9
13.08
15.00
10
13.2
12.50
12.12
215.00 102.50
12.24
If it is needed to adjust the output voltage higher or lower than the converter’s nominal value use the table above to determine appropriate
resistor values, insuring that the voltage is within the adjustment range for the converter used.
If no voltage adjustment is needed connect a 470pF ceramic capacitor from pin 6 to ground.
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R1.A
Tel: +1 514 620 2722
6 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only