Series AM1L-FZ
1 Watt | DC-DC Converter
Output Specifications
Parameters
Voltage accuracy
Conditions
Typical
Maximum
Units
%
%
Nominal input
1
3
±1
5
Voltage balance (Dual Output Models)
Balanced Load
25% load on one output - 100% load on
second load
%
Cross Regulation (Dual Output Models)
Short Circuit protection
Line voltage regulation
Max 1 second
Per 1% of Vin Change
Output current change from 20% to 100%
max load
Output current change from 20% to 100%
max load
1.2
12
%
%
8
9
Load voltage regulation (Single)
Load voltage regulation (Dual)
12
%
Temperature coefficient
Ripple & Noise
Nominal Input
20MHz Bandwidth
±0.01
100
±0.02
%/oC
mV p-p
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Derating
Conditions
100% load
Typical
100(Min 70KHz)
-40 to +85
Maximum
Units
150
100
90
KHz
oC
-55 to +125
oC
oC
No derating up to +85 oC
Cooling
Humidity
Case material
Weight
Free Air Convection
% RH
g
Plastic (UL94-V0)
1.6/2.1
Dimensions (L x W x H)
1KVdc isolation single output models :0.50 x 0.44 x 0.29 inches 12.80 x 11.20 x 7.40 mm
All other models :0.60 x 0.44 x 0.29 inches 15.20 x 11.20 x 7.40 mm
3000k hours
MTBF
Maximum soldering temperature
300 (1.5mm from case for 10 seconds)
oC
Pin Out Specifications
Pin
1000VDC
Single
1
2
3
4
5
6
7
8
-V Input
+V Input
No Pin
-V Output
+V Output
No Pin
No Pin
N.C
Pin
1000VDC
Dual
-V Input
+V Input
No Pin
Common
-V Output
No Pin
+V Output
No Pin
3000VDC
Single
-V Input
+V Input
No Pin
-V Output
N.C.
No Pin
+V Output
No Pin
No Pin
N.C.
Dual
-V Input
+V Input
No Pin
Common
-V Output
No Pin
+V Output
No Pin
No Pin
1
2
3
4
5
6
7
8
9
No Pin
N.C.
10
N.C.
Block Diagrams
www.aimtec.com
F 051e R12.A
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only